Market IndexProduct intelligenceSolar and hybrid invertersSearch products
All marketsResidential solar and hybrid invertersNorthern Electric Power

Northern Electric Power · BDM-800-240A

BDM-800 Microinverter

A two-module 240V microinverter with 22 to 55V MPPT, transformer isolation and PLC or model-specific Wi-Fi monitoring paths
Market statusCurrent isolated dual-module NEP microinverterChecked Aug 19
Reference price$220 current U.S. retail priceExact BDM-800 inverter only before trunk cable, end caps, BDG gateway or Wi-Fi configuration, combiner, roof labor, permit, freight and tax
Product cyclecurrentRelease history under review
EvidenceWell supported8 publishers · 4 independent
Next full checkAug 26, 2026Price checks run sooner
01

Ready to buy

Lock the exact one-line and equipment suffixes

The retained equipment reference is $220 current U.S. retail price. Confirm 240A rather than 208A or international output, PLC versus Wi-Fi generation and the current AC connector before ordering. Require string or branch calculations, exact listings, settings, permit and utility scope, commissioning exports, credentials, warranty labor and final installed price.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$220 current U.S. retail price

Confirm 240A rather than 208A or international output, PLC versus Wi-Fi generation and the current AC connector before ordering. Confirm authorized U.S. stock, tax, freight, accessories, design, installation, warranty and return terms before paying.

Checked 5 days agoDirect source1 evidence item

Conversion architecture

isolated dual-module microinverter
Checked 5 days agoOur synthesis3 evidence items

String, microinverter and hybrid boundary

BDM-800-240A serves two modules and uses an isolated microinverter topology. The isolation choice, two-module fault domain and PLC or Wi-Fi generation distinguish it from transformerless one- and four-module alternatives
Checked 5 days agoOur synthesis2 evidence items

Power, current and MPPT limits

The current U.S. manual gives 768W at 240V, two 17A DC inputs, 20A absolute Isc per input, 22 to 55V MPPT and 60V maximum DC. Both modules require cold-Voc and operating-current checks
Checked 5 days agoOur synthesis2 evidence items

Module, MLPE, RSD and battery ecosystem

The exact AC daisy-chain connector, caps, BDG-256 gateway and generation-specific communications belong on the parts list. Compatibility with older BDM models does not authorize mixed connector or firmware assumptions
Checked 5 days agoDirect source2 evidence items

Service, transfer, islanding and loads

The manual allows five 240V units on its stated 20A branch basis, subject to the adopted code and exact conductor and temperature design. It follows the grid and cannot island without a separately listed AC-coupled storage and transfer system
Checked 5 days agoOur synthesis4 evidence items

AFCI, GFDI, listings, code and utility

The current record identifies UL 1741 SA/SB, Rule 21, integrated ground-fault detection and NEMA 6 or IP-rated construction. Those listings do not replace rapid-shutdown system proof, grounding, connector, roof-access, breaker, disconnect, label or utility review
Checked 5 days agoOur synthesis4 evidence items

Outdoor, thermal and service siting

Natural convection, roof clearance, module heat, wet-location connectors, supported cabling and service access remain material. Its enclosure rating does not permit submersion, trapped water or unsupported connectors
Checked 5 days agoDirect source2 evidence items

Monitoring, cloud, privacy and offline behavior

PLC models report through the BDG gateway and Wi-Fi models use a different path. Conversion is local, while remote records and alerts depend on the selected gateway, account and cloud; establish account transfer, installer access and data export before handoff
Checked 5 days agoOur synthesis3 evidence items

Warranty, installer and service

Confirm the exact current U.S. product warranty, seller authorization, communications generation, shipping and labor. Limited installer familiarity can make a low-cost roof replacement slower than the hardware price suggests
Checked 5 days agoDirect source3 evidence items

Equipment versus installed cost

Exact BDM-800 inverter only before trunk cable, end caps, BDG gateway or Wi-Fi configuration, combiner, roof labor, permit, freight and tax. Confirm 240A rather than 208A or international output, PLC versus Wi-Fi generation and the current AC connector before ordering
Checked 5 days agoOur synthesis2 evidence items

Yield, savings, backup and permission boundary

The exact inverter can convert power within its tested, listed and commissioned limits, but it cannot guarantee site energy yield, clipping outcome, utility savings, a bill, uptime, outage operation, fire safety, code approval, interconnection or permission to operate, warranty labor or service response.
Checked 5 days agoOur synthesis5 evidence items

Current verdict

The isolated value microinverter

Choose BDM-800 when its isolated topology, dual inputs and price fit a fully documented NEP branch and gateway design with a credible regional replacement path.

Checked 5 days agoOur synthesis12 evidence items
03

Other paths

The alternatives change what the BDM-800 Microinverter is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01ownership

Hoymiles

HMS-2000-4T-NA Microinverter

$371.43 current U.S. retail price
Best fit
four-module microinverter consolidation
Tradeoff
One roof inverter serves four modules with independent input tracking and one 240V AC output. It lowers enclosure and trunk-connection count relative to one-module micros but expands the production area affected by one inverter or AC-port failure
Open the source
02premium

APsystems

DS3-L Microinverter

$265 current manufacturer-direct U.S. price
Best fit
dual-module microinverter value path
Tradeoff
One DS3-L serves two modules through two independent MPPT channels and produces single-phase AC. A shared enclosure reduces roof electronics count but one inverter fault or AC connection affects both attached modules
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact inverter, price and system boundaries retained

    BDM-800 Microinverter was checked against exact manufacturer identity and support, current equipment price, independent equipment evidence, complete electrical, rapid-shutdown, interconnection, monitoring, service and outcome boundaries and bounded owner or installer reports.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $220 current U.S. retail price

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Owner and installer evidence is retained as a design, commissioning and service checklist for BDM-800 Microinverter, especially connector generation, plc visibility, branch behavior, u.s. support and replacement stock, not as a yield, safety or reliability rate.

Reports are self-selected and span different modules, orientations, climates, stringing, branches, services, batteries, generators, utilities, codes, installers, firmware, tariffs, monitoring and system ages. They cannot prove yield, savings, fire safety, code compliance, permission, backup behavior, reliability or service outcomes for another site.
SignalWhat owners reportOur readEvidence

connector generation, PLC visibility, branch behavior, U.S. support and replacement stock

Self-selected owners and installers discuss quotations, stringing, clipping, commissioning, monitoring, firmware, faults, replacement labor and support. Reports are anecdotal, configuration-specific and do not establish yield, savings, safety, reliability or failure rates.

Make the seller identify the exact 240V communications generation and price the gateway and spare-device plan before treating it as a commodity microinverter.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
BDM-800 Microinverter current manufacturer recordNorthern Electric Power · identity

Northern Electric Power identifies exact model BDM-800-240A as a two-module 240V microinverter with 22 to 55V MPPT, transformer isolation and PLC or model-specific Wi-Fi monitoring paths.

Source type
manufacturer
Content hash
fa28204cf44e1a70
Use
store excerpt
Open Northern Electric Power
02
BDM-800 Microinverter current U.S. equipment offersolartekcorp.com · price

$220 current U.S. retail price was retained for exact model BDM-800-240A. Confirm 240A rather than 208A or international output, PLC versus Wi-Fi generation and the current AC connector before ordering

Source type
retailer
Content hash
a5f2509c8041f159
Use
store snapshot
Open solartekcorp.com
03
BDM-800 Microinverter current specification and manualNorthern Electric Power · specification

BDM-800-240A serves two modules and uses an isolated microinverter topology. The isolation choice, two-module fault domain and PLC or Wi-Fi generation distinguish it from transformerless one- and four-module alternatives The current U.S. manual gives 768W at 240V, two 17A DC inputs, 20A absolute Isc per input, 22 to 55V MPPT and 60V maximum DC. Both modules require cold-Voc and operating-current checks The exact AC daisy-chain connector, caps, BDG-256 gateway and generation-specific communications belong on the parts list. Compatibility with older BDM models does not authorize mixed connector or firmware assumptions

Source type
support
Content hash
a4017ef05b1c08d9
Use
store excerpt
Open Northern Electric Power
04
BDM-800 Microinverter current support and service pathNorthern Electric Power · specification

The manual allows five 240V units on its stated 20A branch basis, subject to the adopted code and exact conductor and temperature design. It follows the grid and cannot island without a separately listed AC-coupled storage and transfer system The current record identifies UL 1741 SA/SB, Rule 21, integrated ground-fault detection and NEMA 6 or IP-rated construction. Those listings do not replace rapid-shutdown system proof, grounding, connector, roof-access, breaker, disconnect, label or utility review Natural convection, roof clearance, module heat, wet-location connectors, supported cabling and service access remain material. Its enclosure rating does not permit submersion, trapped water or unsupported connectors Confirm the exact current U.S. product warranty, seller authorization, communications generation, shipping and labor. Limited installer familiarity can make a low-cost roof replacement slower than the hardware price suggests

Source type
support
Content hash
3bf517cb4d45e6a6
Use
store excerpt
Open Northern Electric Power
05
BDM-800 Microinverter monitoring, cloud and privacy boundaryNorthern Electric Power · software

PLC models report through the BDG gateway and Wi-Fi models use a different path. Conversion is local, while remote records and alerts depend on the selected gateway, account and cloud; establish account transfer, installer access and data export before handoff

Source type
support
Content hash
27c95acbef6c993c
Use
store excerpt
Open Northern Electric Power
06
NEP BDM-800-240A equipment listingCalifornia Energy Commission · specification

The current independent equipment database retains model BDM-800-240A with its tested AC rating, voltage, efficiency and grid-support identity. A database listing does not approve a roof, string, battery, grid profile or utility interconnection.

Source type
editorial
Content hash
2de7b62641d1ba55
Use
store excerpt
Open California Energy Commission
07
Homeowner's guide to going solarU.S. Department of Energy · specification

DOE separates equipment ratings from site design, production estimates, bids, financing, installation, permits, interconnection and operating results. A solar proposal remains site- and contract-specific.

Source type
editorial
Content hash
e615d058921b1f47
Use
store excerpt
Open U.S. Department of Energy
08
Solar interconnection standards and policiesU.S. Department of Energy · specification

Interconnection requires the serving utility's application, technical review, approved equipment and operating settings. An inverter listing or installer promise does not grant permission to export or operate.

Source type
support
Content hash
7471e65e9c86d429
Use
store excerpt
Open U.S. Department of Energy
09
Solar photovoltaic electrical and fire-safety resourcesNational Fire Protection Association · specification

PV equipment remains energized from multiple sources and must follow adopted electrical, rapid-shutdown, disconnect, labeling, access and fire-safety requirements. A listed component does not prove a complete installation compliant.

Source type
editorial
Content hash
9f66db067ada0952
Use
store excerpt
Open National Fire Protection Association
10
NEP BDM-800 microinverter owner and installer discussionsSolar owners and installers · consensus

Self-selected owners and installers discuss quotations, stringing, clipping, commissioning, monitoring, firmware, faults, replacement labor and support. Reports are anecdotal, configuration-specific and do not establish yield, savings, safety, reliability or failure rates.

Source type
community
Content hash
776b4acc2ea723ff
Use
store excerpt
Open Solar owners and installers
11
HMS-2000-4T-NA Microinverter comparison alternativeHoymiles · alternative

HMS-2000-4T-NA Microinverter is the four-module microinverter consolidation alternative at $371.43 current U.S. retail price.

Source type
manufacturer
Content hash
3a518b72c76f1257
Use
store excerpt
Open Hoymiles
12
DS3-L Microinverter comparison alternativeAPsystems · alternative

DS3-L Microinverter is the dual-module microinverter value path alternative at $265 current manufacturer-direct U.S. price.

Source type
manufacturer
Content hash
9c8e9dc67d879189
Use
store excerpt
Open APsystems

Manufacturer identity, exact model specification or manual, current U.S. support and equipment price, independent equipment or utility evidence and bounded owner or installer evidence were checked on August 19, 2026. This market covers current U.S.-supported residential grid-tied solar, microinverter, battery-ready, hybrid and inverter-charger systems whose conversion, module electronics, battery, service or islanding architecture materially changes the buyer decision. It excludes battery systems counted again as inverters, capacity-only siblings, OEM rebadges, bare optimizers and rapid-shutdown parts, commercial-only three-phase platforms, unsupported imports, obsolete systems and installer proposals without model-level equipment. Preserve exact nominal and continuous AC power, timed peak, output current and service voltage; MPPT count, voltage, current and short-circuit limits; module, optimizer, receiver, trunk and connector compatibility; DC/AC oversizing and clipping assumptions; battery voltage, protocol and approved models; pass-through versus inverter output; backed-up circuits, transfer, neutral, generator and islanding equipment. AFCI, GFDI, rapid shutdown, disconnects, OCPD, PCS, UL 1741, UL 3741, UL 9540, IEEE 1547 and other listings apply to exact configurations and do not replace adopted NEC, fire access, permit, utility grid profile, interconnection review or permission to operate. Outdoor ratings do not waive thermal derating, sun, snow, water, conduit, structure, clearance, noise and service access. Preserve local controls, installer credentials, app, gateway, cloud, privacy, firmware, offline behavior, warranty, authorized channel, parts and labor. Equipment price excludes the complete array, batteries, gateways, transfer equipment, panels, design, installation, roof work, service upgrades, permits, utility costs, tax and financing. No nameplate, optimizer, MPPT, efficiency, clipping model, production forecast, backup rating, warranty, quote, app or certification guarantees energy yield, savings, bill, uptime, outage performance, permission, fire safety, code approval or service outcome.

Researching another model?

Search the current market