Market IndexProduct intelligencePower-quality analyzersSearch products
All marketsProfessional power-quality analyzersFluke

Fluke · 1775

1775 Three-Phase Power Quality Analyzer

A portable four-voltage and four-current Class A analyzer with automatic power-quality logging, 1 MS/s transient capture and guided onsite analysis
Market statusCurrent Class A analyzer with 1 MS/s transient captureChecked Aug 18
Reference price$9,942.81 current authorized U.S. street referenceTEquipment exact current model 1775 package
Product cyclecurrentRelease history under review
EvidenceWell supported6 publishers · 3 independent
Next full checkAug 25, 2026Price checks run sooner
01

Ready to buy

Quote the analyzer, sensors, software and service

The retained reference is $9,942.81 current authorized U.S. street reference. Confirm catalog 5117278 and every included probe, communications module and case; BASIC pricing omits material parts. Commission wiring, sensor orientation, clock, triggers, storage, export and safe removal on a known source before consequential work.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$9,942.81 current authorized U.S. street reference

Confirm catalog 5117278 and every included probe, communications module and case; BASIC pricing omits material parts. Confirm current checkout or written authorized quote, seller status, package contents, calibration and return rights before paying.

Refresh due soonDirect source1 evidence item

Market branch

Mainstream transient-aware three-phase troubleshooting
Checked 6 days agoOur synthesis2 evidence items

Exact instrument and package

The retained 1775 is the complete catalog 5117278 package with four 1500 A iFlex probes, magnetic probes, soft case and Wi-Fi/Bluetooth module; BASIC and FPC packages are not equivalent
Checked 6 days agoOur synthesis3 evidence items

Standards, class and edition

The platform applies IEC 61000-4-30 Edition 3 Class A methods; EN 50160 or IEEE 519 outputs remain analysis configurations rather than universal pass or fail judgments
Checked 6 days agoOur synthesis3 evidence items

Inputs, topology and range

Four voltage and four current channels cover the supported AC and DC wiring topologies and sensor-dependent ranges; the two auxiliary inputs need appropriate transducers and scaling
Checked 6 days agoDirect source2 evidence items

Events, waveforms and transients

One MS/s transient capture distinguishes 1775 from 1773, alongside automatic dips, swells, interruptions, inrush and event waveforms; trigger configuration controls what is retained
Checked 6 days agoOur synthesis3 evidence items

Harmonics, flicker and aggregation

Harmonics, higher-frequency content, unbalance, flicker, power and energy are recorded within manual bandwidth, aggregation and sensor conditions
Checked 6 days agoOur synthesis2 evidence items

Clock and time synchronization

Clock configuration, optional synchronization path and time zone must be documented before cross-device or utility correlation
Checked 6 days agoOur synthesis2 evidence items

Sensors, leads and package

Four 1500 A iFlex probes and magnetic voltage probes are in the retained package; conductor fit, orientation, flexible-loop closure and sensor bandwidth remain installation evidence
Checked 6 days agoOur synthesis3 evidence items

Software, storage and data access

Energy Analyze Plus and local display support field setup and reporting, with USB, Ethernet and wireless paths dependent on module, software version, permissions and cyber policy
Checked 6 days agoOur synthesis3 evidence items

Battery, phase power and enclosure

Battery and line-power options support mobile surveys, but battery endurance, charger, measured-circuit supply and closed-panel mounting need a site-specific plan
Checked 6 days agoOur synthesis2 evidence items

Calibration, support and service

Fluke provides repair and calibration access; analyzer and current probes need retained serials, intervals, uncertainty requirements and separately confirmed accredited scope
Checked 6 days agoOur synthesis2 evidence items

Category, installation and qualified work

The instrument never authorizes live connection; qualified-work rules, source de-energization, PPE, approach boundaries, lead inspection, secure strain relief and panel closure govern the job
Checked 6 days agoOur synthesis3 evidence items

No diagnosis, compliance or safety guarantee

No standards class, category mark, input count, sample rate, trigger, waveform, harmonic result, GPS lock, calibration, report, review or owner account guarantees root cause, utility responsibility, code compliance, equipment condition, safe work or a successful corrective action. Follow the exact manuals and the employer's qualified electrical-safety program.
Checked 6 days agoOur synthesis5 evidence items

Current verdict

The balanced 1770-series analyzer

1775 is the coherent 1770-series middle choice when transient capture is required but the 1777's 20 MS/s acquisition and hard-case premium are not justified.

Checked 6 days agoOur synthesis10 evidence items
03

Other paths

The alternatives change what the 1775 Three-Phase Power Quality Analyzer is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01lower upfront

Fluke

1773 Three-Phase Power Quality Analyzer

$7,983.66 current authorized U.S. street reference
Best fit
Class A surveys without fast transients
Tradeoff
Catalog 5117269 includes four 1500 A iFlex probes but no magnetic voltage probes, case or Wi-Fi/Bluetooth module and no fast-transient detection; those omissions must be priced explicitly
Open the source
02premium

Fluke

1777 Three-Phase Power Quality Analyzer

$12,980.52 current authorized U.S. street reference
Best fit
Fast-transient and advanced three-phase investigation
Tradeoff
The retained 1777 package is catalog 5126630 with four 1500 A iFlex probes, magnetic voltage probes, hard case and Wi-Fi/Bluetooth module; BASIC, FPC, LTE, other clamp ranges and calibration packages are separate
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact system and evidence retained

    1775 Three-Phase Power Quality Analyzer was checked against manufacturer identity and manual, current U.S. exact-package price, independent professional coverage, bounded operator evidence and explicit standards, input, sensor, software, calibration, service and safety boundaries.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $9,942.81 current authorized U.S. street reference

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Operator discussion is retained as a checklist for automatic setup, transient thresholds, battery endurance, magnetic probes, wireless downloads, report setup and training demand, not as an accuracy, safety, reliability or outcome rate.

These self-selected reports span different analyzer revisions, sensors, leads, circuits, thresholds, firmware, software, calibration states, environments, employers and operator skill. They cannot prove that another installation, record, diagnosis or procedure is accurate or safe.
SignalWhat owners reportOur readEvidence

automatic setup, transient thresholds, battery endurance, magnetic probes, wireless downloads, report setup and training demand

Operators report both successful work and friction involving automatic setup, transient thresholds, battery endurance, magnetic probes, wireless downloads, report setup and training demand.

Compare one MS/s captures with the actual disturbance duration and prove the complete report path before paying for transient capability.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
1775 Three-Phase Power Quality Analyzer official identity and specificationFluke · identity

Fluke identifies exact model 1775 as a portable four-voltage and four-current Class A analyzer with automatic power-quality logging, 1 MS/s transient capture and guided onsite analysis. The platform applies IEC 61000-4-30 Edition 3 Class A methods; EN 50160 or IEEE 519 outputs remain analysis configurations rather than universal pass or fail judgments

Source type
manufacturer
Content hash
0a441ae790dffeea
Use
store excerpt
Open Fluke
02
1775 Three-Phase Power Quality Analyzer current U.S. exact-package priceTEquipment · price

$9,942.81 current authorized U.S. street reference is retained for exact model 1775 under the stated package boundary. Confirm catalog 5117278 and every included probe, communications module and case; BASIC pricing omits material parts

Source type
retailer
Content hash
0dc14eb8b5985d87
Use
store snapshot
Open TEquipment
03
1775 Three-Phase Power Quality Analyzer official manual and operating limitsFluke · specification

Four voltage and four current channels cover the supported AC and DC wiring topologies and sensor-dependent ranges; the two auxiliary inputs need appropriate transducers and scaling One MS/s transient capture distinguishes 1775 from 1773, alongside automatic dips, swells, interruptions, inrush and event waveforms; trigger configuration controls what is retained Harmonics, higher-frequency content, unbalance, flicker, power and energy are recorded within manual bandwidth, aggregation and sensor conditions Four 1500 A iFlex probes and magnetic voltage probes are in the retained package; conductor fit, orientation, flexible-loop closure and sensor bandwidth remain installation evidence

Source type
support
Content hash
424ba8390104c335
Use
store excerpt
Open Fluke
04
Fluke software, calibration and service pathFluke · software

Energy Analyze Plus and local display support field setup and reporting, with USB, Ethernet and wireless paths dependent on module, software version, permissions and cyber policy Fluke provides repair and calibration access; analyzer and current probes need retained serials, intervals, uncertainty requirements and separately confirmed accredited scope

Source type
support
Content hash
6a5249ce33d8d0bd
Use
store excerpt
Open Fluke
05
Qualified electrical work and hazard-control boundaryOSHA · specification

Electrical work around exposed energized parts requires qualified-person boundaries, de-energization where feasible, hazard assessment and appropriate practices and protective equipment. An analyzer does not authorize live work.

Source type
support
Content hash
bb02fba2730aa8f5
Use
store excerpt
Open OSHA
06
Portable power logger voltage-lead hazard evidenceFluke safety notice · consensus

Fluke's critical alert for 173x and 174x voltage leads demonstrates that the complete lead set, connection sequence and current safety-notice state must be checked for every brand and deployment; a CAT label alone is insufficient.

Source type
editorial
Content hash
4c7366b1593d18d8
Use
store excerpt
Open Fluke safety notice
07
Fluke 1770-series field workflow evidence through the 1777C&C Technology Group · specification

Independent professional coverage examines the exact product or closest retained family system for field setup, package, controls, data, software or ownership. It cannot establish performance for another configuration, sensor, circuit, trigger, firmware or operator.

Source type
editorial
Content hash
1198e9e24fe0c07a
Use
store excerpt
Open C&C Technology Group
08
1775 Three-Phase Power Quality Analyzer current operator discussionsPower-quality technicians and electrical professionals · consensus

Self-selected operators discuss automatic setup, transient thresholds, battery endurance, magnetic probes, wireless downloads, report setup and training demand. Reports span different circuits, sensors, firmware, thresholds, intervals, software, calibration states and skill and cannot establish accuracy, safety or failure rates.

Source type
community
Content hash
afda51f8447802e4
Use
store excerpt
Open Power-quality technicians and electrical professionals
09
1773 Three-Phase Power Quality Analyzer comparison alternativeFluke · alternative

1773 Three-Phase Power Quality Analyzer represents the class a surveys without fast transients branch at $7,983.66 current authorized U.S. street reference.

Source type
manufacturer
Content hash
86dc7ee04a252bfe
Use
store excerpt
Open Fluke
10
1777 Three-Phase Power Quality Analyzer comparison alternativeFluke · alternative

1777 Three-Phase Power Quality Analyzer represents the fast-transient and advanced three-phase investigation branch at $12,980.52 current authorized U.S. street reference.

Source type
manufacturer
Content hash
7c2711686414be5d
Use
store excerpt
Open Fluke

Manufacturer identity, specifications, manual or support, current U.S. price or list-price boundary, independent professional coverage, bounded operator discussion and U.S. calibration or service were checked on August 18, 2026. This desk covers complete current or currently supported portable professional power-quality analyzers and loggers that measure and time-record power-quality parameters for qualified electrical work. It excludes ordinary multimeters and clamp meters, basic plug-in monitors, benchtop oscilloscopes, protective relays, permanent panel meters, bare sensors, obsolete systems and cosmetic or service bundles counted as products. Preserve exact standards class and edition; line topology; voltage and current inputs; CAT and input limits; sensor type, range, bandwidth, orientation and connector; event, waveform, transient, harmonic, interharmonic, flicker and aggregation behavior; time synchronization; storage; software, firmware, licenses, cloud and export; battery, phase power, ingress state, mounting, calibration, service and safety-alert status. No reading, event, standard, report, review or owner account establishes root cause, code compliance, safe work, equipment health, utility responsibility or a guaranteed outcome.

Researching another model?

Search the current market