The facts that change the ownership choice
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
Current price
$7,983.66 current authorized U.S. street referenceConfirm catalog 5117269, its four iFlex probes and omitted case, magnetic probes, communications module and transient function. Confirm current checkout or written authorized quote, seller status, package contents, calibration and return rights before paying.
Refresh due soonDirect source1 evidence itemMarket branch
Class A surveys without fast transients
Checked 6 days agoOur synthesis2 evidence itemsExact instrument and package
Catalog 5117269 includes four 1500 A iFlex probes but no magnetic voltage probes, case or Wi-Fi/Bluetooth module and no fast-transient detection; those omissions must be priced explicitly
Checked 6 days agoOur synthesis3 evidence itemsStandards, class and edition
IEC 61000-4-30 Edition 3 Class A parameter methods are retained, while compliance reports still require the correct nominal values, observation period, thresholds and jurisdictional rule set
Checked 6 days agoOur synthesis3 evidence itemsInputs, topology and range
The four voltage and four current architecture supports the documented single- and three-phase connections and sensor-dependent ranges; auxiliary channels need separate transducers
Checked 6 days agoDirect source2 evidence itemsEvents, waveforms and transients
Dips, swells, interruptions, rapid changes and inrush can be logged, but 1773 has no 1 MS/s or 20 MS/s fast-transient function and cannot be upgraded by adding probes
Checked 6 days agoOur synthesis3 evidence itemsHarmonics, flicker and aggregation
Power, energy, imbalance, flicker and harmonic trends are available within the stated frequency, aggregation and sensor limits
Checked 6 days agoOur synthesis2 evidence itemsClock and time synchronization
Use the documented clock and synchronization options, verify drift and time zone, and retain settings with every survey export
Checked 6 days agoOur synthesis2 evidence itemsSensors, leads and package
Four 1500 A iFlex probes are included; magnetic voltage probes, a case, low-current or DC sensors and communications accessories remain separate
Checked 6 days agoOur synthesis3 evidence itemsSoftware, storage and data access
Energy Analyze Plus provides download and analysis; USB is part of the base workflow while wireless use requires the separately purchased module and compatible software
Checked 6 days agoOur synthesis3 evidence itemsBattery, phase power and enclosure
Portable battery and supported line-power operation do not remove the need for secure mounting, ventilation, access control and a plan for loss of supply
Checked 6 days agoOur synthesis2 evidence itemsCalibration, support and service
Fluke service supports calibration and repair, but probe accuracy, instrument adjustment, accredited results and field verification are distinct line items
Checked 6 days agoOur synthesis2 evidence itemsCategory, installation and qualified work
A lower feature level is not a lower hazard level; category, voltage, lead, probe, PPE, absence-of-voltage and qualified-person controls are unchanged
Checked 6 days agoOur synthesis3 evidence itemsNo diagnosis, compliance or safety guarantee
No standards class, category mark, input count, sample rate, trigger, waveform, harmonic result, GPS lock, calibration, report, review or owner account guarantees root cause, utility responsibility, code compliance, equipment condition, safe work or a successful corrective action. Follow the exact manuals and the employer's qualified electrical-safety program.
Checked 6 days agoOur synthesis5 evidence itemsCurrent verdict
The Class A 1770-series entry1773 is defensible for guided Class A surveys and ordinary event logging when fast transients and wireless field control are outside the written measurement plan.
Checked 6 days agoOur synthesis10 evidence items