The facts that change the ownership choice
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
Current price
$9,695 current AEMC U.S. list-price boundaryObtain an authorized quote for catalog 2136.35 or the exact sensor kit and add current probes, calibration, shipping and return terms before comparison. Confirm current checkout or written authorized quote, seller status, package contents, calibration and return rights before paying.
Refresh due soonDirect source1 evidence itemMarket branch
Class A surge and multi-input analysis
Checked 6 days agoOur synthesis2 evidence itemsExact instrument and package
Catalog 2136.35 is the in-stock factory base analyzer with leads, power adapter, battery, SD card and bag but no current probes; catalogs 2136.36 and 2136.37 add materially different sensor packages
Checked 6 days agoOur synthesis3 evidence itemsStandards, class and edition
AEMC states IEC 61000-4-30 Edition 3 Class A certification, IEC 61000-4-7 harmonics, IEC 61000-4-15 flicker and IEEE 1459 power methods; report limits remain configuration dependent
Checked 6 days agoOur synthesis3 evidence itemsInputs, topology and range
Five voltage terminals and four current inputs support one-, two- and three-phase systems to the manual's 1000 V and sensor-dependent ranges
Checked 6 days agoDirect source2 evidence itemsEvents, waveforms and transients
Trend logging can reach 200 ms, while transient, inrush and shockwave modes retain different windows and rates; surge mode reaches the stated 500 ns sample condition and 12 kV boundary
Checked 6 days agoOur synthesis3 evidence itemsHarmonics, flicker and aggregation
Harmonics and interharmonics, flicker, mains signaling, imbalance, power and energy are calculated under their named standards and intervals
Checked 6 days agoOur synthesis2 evidence itemsClock and time synchronization
Internal GPS supports Class A timing and multi-device correlation only when lock, antenna placement, time zone and retained status evidence are verified
Checked 6 days agoOur synthesis2 evidence itemsSensors, leads and package
The $9,695 base unit omits current probes; MA194, 193, MN193, MR193, E94 and other sensors have distinct ranges, bandwidths, categories, connector and calibration costs
Checked 6 days agoOur synthesis3 evidence itemsSoftware, storage and data access
DataView, the PowerPad IV control panel, USB, Ethernet, Wi-Fi, VNC and email alarms require supported software, network access, credentials and secure remote configuration
Checked 6 days agoOur synthesis3 evidence itemsBattery, phase power and enclosure
A battery and the PA32ER phase-power adapter support portable use; battery state, input-power lead ratings, IP54 enclosure boundary and mounting remain part of the survey
Checked 6 days agoOur synthesis2 evidence itemsCalibration, support and service
AEMC offers Dover, New Hampshire repair and calibration and lists optional NIST service; exact accredited scope, probe coverage, pre/post results and interval must be ordered
Checked 6 days agoOur synthesis2 evidence itemsCategory, installation and qualified work
1000 V CAT IV applies only to the marked analyzer and complete input system; live connection belongs to qualified workers using approved leads, sensors, PPE, sequence and controlled access
Checked 6 days agoOur synthesis3 evidence itemsNo diagnosis, compliance or safety guarantee
No standards class, category mark, input count, sample rate, trigger, waveform, harmonic result, GPS lock, calibration, report, review or owner account guarantees root cause, utility responsibility, code compliance, equipment condition, safe work or a successful corrective action. Follow the exact manuals and the employer's qualified electrical-safety program.
Checked 6 days agoOur synthesis5 evidence itemsCurrent verdict
The open-sensor Class A platform8345 is strongest when Class A Edition 3, 1000 V CAT IV, surge capture and flexible sensor selection justify commissioning a complete probe package separately.
Checked 6 days agoOur synthesis10 evidence items