Market IndexProduct intelligencePower-quality analyzersSearch products
All marketsProfessional power-quality analyzersAEMC Instruments

AEMC Instruments · 8336 / 2136.30

PowerPad III 8336

A portable five-voltage and four-current-input analyzer with trend recording, inrush, 210 transient captures, alarms, harmonics, flicker and DataView software
Market statusCurrent PowerPad III analyzer without current probesChecked Aug 18
Reference price$5,900 current AEMC U.S. list-price boundaryAEMC catalog 2136.30 factory-listed analyzer without probes
Product cyclecurrentRelease history under review
EvidenceWell supported5 publishers · 3 independent
Next full checkAug 25, 2026Price checks run sooner
01

Ready to buy

Quote the analyzer, sensors, software and service

The retained reference is $5,900 current AEMC U.S. list-price boundary. Obtain an authorized quote for 2136.30 and add four fit-for-purpose current sensors, calibration and delivery; do not compare it with complete kits as if package content matched. Commission wiring, sensor orientation, clock, triggers, storage, export and safe removal on a known source before consequential work.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$5,900 current AEMC U.S. list-price boundary

Obtain an authorized quote for 2136.30 and add four fit-for-purpose current sensors, calibration and delivery; do not compare it with complete kits as if package content matched. Confirm current checkout or written authorized quote, seller status, package contents, calibration and return rights before paying.

Refresh due soonDirect source1 evidence item

Market branch

General multi-input PQ troubleshooting
Checked 6 days agoOur synthesis2 evidence items

Exact instrument and package

Catalog 2136.30 is the factory in-stock analyzer without probes; 2136.31 and 2136.32 add four different sensor types and materially different list prices
Checked 6 days agoOur synthesis3 evidence items

Standards, class and edition

8336 supports IEC-based power-quality parameters and EN 50160 analysis but is not the 8345's IEC 61000-4-30 Edition 3 Class A platform; preserve that distinction in any compliance use
Checked 6 days agoOur synthesis3 evidence items

Inputs, topology and range

Five voltage terminals and four current inputs create four voltage and four current channels for supported single- and three-phase systems to sensor-dependent current limits
Checked 6 days agoDirect source2 evidence items

Events, waveforms and transients

The platform stores trends, inrush, alarms, screen captures and up to the documented 210 transient records; record length and trigger setup compete for memory and evidence
Checked 6 days agoOur synthesis3 evidence items

Harmonics, flicker and aggregation

Harmonics through the documented order, flicker, unbalance, power, energy and waveform views remain method, range and interval dependent
Checked 6 days agoOur synthesis2 evidence items

Clock and time synchronization

Local clock and software timestamps support one-instrument surveys but do not provide the 8345's retained internal GPS Class A timing chain
Checked 6 days agoOur synthesis2 evidence items

Sensors, leads and package

The base price has no current probes; AmpFlex, MiniFlex and clamp packages differ in range, conductor fit, AC or DC response and combined accuracy
Checked 6 days agoOur synthesis3 evidence items

Software, storage and data access

DataView and the PowerPad III control panel handle setup, downloads, EN 50160 and exports; the current software release, USB path and Windows support must be proved
Checked 6 days agoOur synthesis3 evidence items

Battery, phase power and enclosure

A rechargeable battery and optional phase-power adapter support field use; runtime, charger, environmental rating and secure unattended placement remain installation constraints
Checked 6 days agoOur synthesis2 evidence items

Calibration, support and service

AEMC lists factory repair, annual recalibration guidance and optional NIST service; define whether current sensors and pre/post data are included
Checked 6 days agoOur synthesis2 evidence items

Category, installation and qualified work

600 V CAT IV and 1000 V CAT III markings remain input-chain and procedure dependent; the analyzer does not choose PPE or make energized attachment safe
Checked 6 days agoOur synthesis3 evidence items

No diagnosis, compliance or safety guarantee

No standards class, category mark, input count, sample rate, trigger, waveform, harmonic result, GPS lock, calibration, report, review or owner account guarantees root cause, utility responsibility, code compliance, equipment condition, safe work or a successful corrective action. Follow the exact manuals and the employer's qualified electrical-safety program.
Checked 6 days agoOur synthesis5 evidence items

Current verdict

The mature general PowerPad

8336 remains a defensible multi-input field analyzer when its non-Class-A position is acceptable and the buyer values inrush, transient and long trend functions at a lower base cost.

Checked 6 days agoOur synthesis10 evidence items
03

Other paths

The alternatives change what the PowerPad III 8336 is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01lower upfront

AEMC Instruments

PowerPad III 8333

$4,195 current AEMC U.S. list-price boundary
Best fit
Lower-cost displayed PQ surveys
Tradeoff
Catalog 2136.10 is the in-stock base meter without probes; 2136.11 and 2136.12 add three distinct sensor packages and must not be treated as cosmetic bundles
Open the source
02premium

AEMC Instruments

PowerPad IV 8345

$9,695 current AEMC U.S. list-price boundary
Best fit
Class A surge and multi-input analysis
Tradeoff
Catalog 2136.35 is the in-stock factory base analyzer with leads, power adapter, battery, SD card and bag but no current probes; catalogs 2136.36 and 2136.37 add materially different sensor packages
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact system and evidence retained

    PowerPad III 8336 was checked against manufacturer identity and manual, current U.S. exact-package price, independent professional coverage, bounded operator evidence and explicit standards, input, sensor, software, calibration, service and safety boundaries.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $5,900 current AEMC U.S. list-price boundary

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Operator discussion is retained as a checklist for probe selection, dataview setup, transient memory, inrush capture, battery age, usb workflow and class a comparison, not as an accuracy, safety, reliability or outcome rate.

These self-selected reports span different analyzer revisions, sensors, leads, circuits, thresholds, firmware, software, calibration states, environments, employers and operator skill. They cannot prove that another installation, record, diagnosis or procedure is accurate or safe.
SignalWhat owners reportOur readEvidence

probe selection, DataView setup, transient memory, inrush capture, battery age, USB workflow and Class A comparison

Operators report both successful work and friction involving probe selection, dataview setup, transient memory, inrush capture, battery age, usb workflow and class a comparison.

Confirm that non-Class-A evidence is acceptable to the client and run a full capture and export with the purchased sensor set.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
PowerPad III 8336 official identity and specificationAEMC Instruments · identity

AEMC Instruments identifies exact model 8336 / 2136.30 as a portable five-voltage and four-current-input analyzer with trend recording, inrush, 210 transient captures, alarms, harmonics, flicker and DataView software. 8336 supports IEC-based power-quality parameters and EN 50160 analysis but is not the 8345's IEC 61000-4-30 Edition 3 Class A platform; preserve that distinction in any compliance use

Source type
manufacturer
Content hash
2b3501786a694189
Use
store excerpt
Open AEMC Instruments
02
PowerPad III 8336 current U.S. exact-package priceAEMC Instruments · price

$5,900 current AEMC U.S. list-price boundary is retained for exact model 8336 / 2136.30 under the stated package boundary. Obtain an authorized quote for 2136.30 and add four fit-for-purpose current sensors, calibration and delivery; do not compare it with complete kits as if package content matched

Source type
manufacturer
Content hash
b117fec70eb6ab08
Use
store snapshot
Open AEMC Instruments
03
PowerPad III 8336 official manual and operating limitsAEMC Instruments · specification

Five voltage terminals and four current inputs create four voltage and four current channels for supported single- and three-phase systems to sensor-dependent current limits The platform stores trends, inrush, alarms, screen captures and up to the documented 210 transient records; record length and trigger setup compete for memory and evidence Harmonics through the documented order, flicker, unbalance, power, energy and waveform views remain method, range and interval dependent The base price has no current probes; AmpFlex, MiniFlex and clamp packages differ in range, conductor fit, AC or DC response and combined accuracy

Source type
support
Content hash
65d4c40f18e5eeb4
Use
store excerpt
Open AEMC Instruments
04
AEMC Instruments software, calibration and service pathAEMC Instruments · software

DataView and the PowerPad III control panel handle setup, downloads, EN 50160 and exports; the current software release, USB path and Windows support must be proved AEMC lists factory repair, annual recalibration guidance and optional NIST service; define whether current sensors and pre/post data are included

Source type
support
Content hash
ffa3984f4e9a111d
Use
store excerpt
Open AEMC Instruments
05
Qualified electrical work and hazard-control boundaryOSHA · specification

Electrical work around exposed energized parts requires qualified-person boundaries, de-energization where feasible, hazard assessment and appropriate practices and protective equipment. An analyzer does not authorize live work.

Source type
support
Content hash
bb02fba2730aa8f5
Use
store excerpt
Open OSHA
06
Portable power logger voltage-lead hazard evidenceFluke safety notice · consensus

Fluke's critical alert for 173x and 174x voltage leads demonstrates that the complete lead set, connection sequence and current safety-notice state must be checked for every brand and deployment; a CAT label alone is insufficient.

Source type
editorial
Content hash
4c7366b1593d18d8
Use
store excerpt
Open Fluke safety notice
07
AEMC 8336 independent product and owner coverageTEquipment · specification

Independent professional coverage examines the exact product or closest retained family system for field setup, package, controls, data, software or ownership. It cannot establish performance for another configuration, sensor, circuit, trigger, firmware or operator.

Source type
editorial
Content hash
1198e9e24fe0c07a
Use
store excerpt
Open TEquipment
08
PowerPad III 8336 current operator discussionsPower-quality technicians and electrical professionals · consensus

Self-selected operators discuss probe selection, dataview setup, transient memory, inrush capture, battery age, usb workflow and class a comparison. Reports span different circuits, sensors, firmware, thresholds, intervals, software, calibration states and skill and cannot establish accuracy, safety or failure rates.

Source type
community
Content hash
83258664b7426f6f
Use
store excerpt
Open Power-quality technicians and electrical professionals
09
PowerPad III 8333 comparison alternativeAEMC Instruments · alternative

PowerPad III 8333 represents the lower-cost displayed pq surveys branch at $4,195 current AEMC U.S. list-price boundary.

Source type
manufacturer
Content hash
343805d69e783c19
Use
store excerpt
Open AEMC Instruments
10
PowerPad IV 8345 comparison alternativeAEMC Instruments · alternative

PowerPad IV 8345 represents the class a surge and multi-input analysis branch at $9,695 current AEMC U.S. list-price boundary.

Source type
manufacturer
Content hash
a025ce0f110761e6
Use
store excerpt
Open AEMC Instruments

Manufacturer identity, specifications, manual or support, current U.S. price or list-price boundary, independent professional coverage, bounded operator discussion and U.S. calibration or service were checked on August 18, 2026. This desk covers complete current or currently supported portable professional power-quality analyzers and loggers that measure and time-record power-quality parameters for qualified electrical work. It excludes ordinary multimeters and clamp meters, basic plug-in monitors, benchtop oscilloscopes, protective relays, permanent panel meters, bare sensors, obsolete systems and cosmetic or service bundles counted as products. Preserve exact standards class and edition; line topology; voltage and current inputs; CAT and input limits; sensor type, range, bandwidth, orientation and connector; event, waveform, transient, harmonic, interharmonic, flicker and aggregation behavior; time synchronization; storage; software, firmware, licenses, cloud and export; battery, phase power, ingress state, mounting, calibration, service and safety-alert status. No reading, event, standard, report, review or owner account establishes root cause, code compliance, safe work, equipment health, utility responsibility or a guaranteed outcome.

Researching another model?

Search the current market