Market IndexProduct intelligencePower-quality analyzersSearch products
All marketsProfessional power-quality analyzersAEMC Instruments

AEMC Instruments · PEL 113 / 2137.54

PEL 113 Power and Energy Logger

A compact displayed logger with four voltage leads, three MiniFlex current sensors, alarms, long records, harmonics and wired or wireless DataView workflows
Market statusCurrent displayed three-phase power and energy logger with sensorsChecked Aug 18
Reference price$2,990 current AEMC U.S. list-price boundaryAEMC catalog 2137.54 PEL 113 package with LCD and three sensors
Product cyclecurrentRelease history under review
EvidenceWell supported6 publishers · 3 independent
Next full checkAug 25, 2026Price checks run sooner
01

Ready to buy

Quote the analyzer, sensors, software and service

The retained reference is $2,990 current AEMC U.S. list-price boundary. Confirm catalog 2137.54, page revision, three MA193-10-BK sensors, voltage leads, DataView and calibration because the no-sensor 2137.64 package is materially different. Commission wiring, sensor orientation, clock, triggers, storage, export and safe removal on a known source before consequential work.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$2,990 current AEMC U.S. list-price boundary

Confirm catalog 2137.54, page revision, three MA193-10-BK sensors, voltage leads, DataView and calibration because the no-sensor 2137.64 package is materially different. Confirm current checkout or written authorized quote, seller status, package contents, calibration and return rights before paying.

Refresh due soonDirect source1 evidence item

Market branch

Cost-controlled displayed energy and harmonic surveys
Checked 6 days agoOur synthesis2 evidence items

Exact instrument and package

Catalog 2137.54 is the $2,990 package with LCD and three MA193-10-BK sensors; catalog 2137.64 omits sensors and newer catalog-number text on the same page must be reconciled on the quote
Checked 6 days agoOur synthesis3 evidence items

Standards, class and edition

The logger supports energy, demand, harmonic and load-study reporting; it is not an IEC 61000-4-30 Class A event analyzer and a report does not establish code compliance
Checked 6 days agoOur synthesis3 evidence items

Inputs, topology and range

Four voltage and three current inputs support single-, split- and three-phase systems to the manual's AC/DC voltage and sensor-dependent current limits
Checked 6 days agoDirect source2 evidence items

Events, waveforms and transients

Long-term Min, Max and Average records and alarms support energy management; there is no fast-transient capture or full Class A event-waveform chain
Checked 6 days agoOur synthesis3 evidence items

Harmonics, flicker and aggregation

Harmonics through the documented order, THD, power, energy, unbalance and demand require correct wiring, nominal values, interval and sensor range
Checked 6 days agoOur synthesis2 evidence items

Clock and time synchronization

The logger clock and network or computer time need confirmation at commissioning; alarm email or remote access is not a precision synchronization claim
Checked 6 days agoOur synthesis2 evidence items

Sensors, leads and package

The retained package has three MA193-10-BK sensors; alternative flexible or AC/DC sensors change range, frequency response, jaw geometry, accuracy and total cost
Checked 6 days agoOur synthesis3 evidence items

Software, storage and data access

DataView, USB, Ethernet, Wi-Fi and remote application paths support setup, live values and reports, subject to compatible firmware, operating system, permissions and network policy
Checked 6 days agoOur synthesis3 evidence items

Battery, phase power and enclosure

Phase or line-cord power and a short backup battery support logging, but mounting, supply interruption, environmental limits and cable strain relief remain installation work
Checked 6 days agoOur synthesis2 evidence items

Calibration, support and service

AEMC's U.S. lab supports repair and calibration; the analyzer and three sensors need exact scope, interval and serial retention
Checked 6 days agoOur synthesis2 evidence items

Category, installation and qualified work

The stated category applies with the exact leads, adapters and current sensors; qualified connection, PPE, panel security and safe removal remain outside the software
Checked 6 days agoOur synthesis3 evidence items

No diagnosis, compliance or safety guarantee

No standards class, category mark, input count, sample rate, trigger, waveform, harmonic result, GPS lock, calibration, report, review or owner account guarantees root cause, utility responsibility, code compliance, equipment condition, safe work or a successful corrective action. Follow the exact manuals and the employer's qualified electrical-safety program.
Checked 6 days agoOur synthesis5 evidence items

Current verdict

The value displayed three-phase logger

PEL 113 is defensible for energy audits, load studies and harmonic trends when its three current channels and non-Class-A, non-waveform-event position match the written job.

Checked 6 days agoOur synthesis10 evidence items
03

Other paths

The alternatives change what the PEL 113 Power and Energy Logger is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01lower upfront

AEMC Instruments

PEL 112 Power and Energy Logger

$2,675 current AEMC U.S. list-price boundary
Best fit
Low-cost displayless energy logging
Tradeoff
Catalog 2137.53 is the in-stock $2,675 no-LCD package with three MA193-10-BK sensors; catalog 2137.63 omits sensors despite inconsistent package prose and needs quote-level reconciliation
Open the source
02premium

Fluke

1736/EUS Three-Phase Power Logger

$6,874.22 current authorized U.S. street reference
Best fit
General load and energy studies with power-quality trends
Tradeoff
The exact 1736/EUS includes four flexible current probes; 1736/B, FPC and the separately priced 1736-to-1738 upgrade are different packages and current feature states
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact system and evidence retained

    PEL 113 Power and Energy Logger was checked against manufacturer identity and manual, current U.S. exact-package price, independent professional coverage, bounded operator evidence and explicit standards, input, sensor, software, calibration, service and safety boundaries.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $2,990 current AEMC U.S. list-price boundary

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Operator discussion is retained as a checklist for lcd value, sensor range, phase adapter, dataview setup, alarms, long files, battery and pel 103 migration, not as an accuracy, safety, reliability or outcome rate.

These self-selected reports span different analyzer revisions, sensors, leads, circuits, thresholds, firmware, software, calibration states, environments, employers and operator skill. They cannot prove that another installation, record, diagnosis or procedure is accurate or safe.
SignalWhat owners reportOur readEvidence

LCD value, sensor range, phase adapter, DataView setup, alarms, long files, battery and PEL 103 migration

Operators report both successful work and friction involving lcd value, sensor range, phase adapter, dataview setup, alarms, long files, battery and pel 103 migration.

Run a representative three-phase log and report with the exact three sensors before accepting the lower price over event-capable analyzers.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
PEL 113 Power and Energy Logger official identity and specificationAEMC Instruments · identity

AEMC Instruments identifies exact model PEL 113 / 2137.54 as a compact displayed logger with four voltage leads, three MiniFlex current sensors, alarms, long records, harmonics and wired or wireless DataView workflows. The logger supports energy, demand, harmonic and load-study reporting; it is not an IEC 61000-4-30 Class A event analyzer and a report does not establish code compliance

Source type
manufacturer
Content hash
64726808f2f79a46
Use
store excerpt
Open AEMC Instruments
02
PEL 113 Power and Energy Logger current U.S. exact-package priceAEMC Instruments · price

$2,990 current AEMC U.S. list-price boundary is retained for exact model PEL 113 / 2137.54 under the stated package boundary. Confirm catalog 2137.54, page revision, three MA193-10-BK sensors, voltage leads, DataView and calibration because the no-sensor 2137.64 package is materially different

Source type
manufacturer
Content hash
0f6768bdc7335ea9
Use
store snapshot
Open AEMC Instruments
03
PEL 113 Power and Energy Logger official manual and operating limitsAEMC Instruments · specification

Four voltage and three current inputs support single-, split- and three-phase systems to the manual's AC/DC voltage and sensor-dependent current limits Long-term Min, Max and Average records and alarms support energy management; there is no fast-transient capture or full Class A event-waveform chain Harmonics through the documented order, THD, power, energy, unbalance and demand require correct wiring, nominal values, interval and sensor range The retained package has three MA193-10-BK sensors; alternative flexible or AC/DC sensors change range, frequency response, jaw geometry, accuracy and total cost

Source type
support
Content hash
4098a8637ab6625e
Use
store excerpt
Open AEMC Instruments
04
AEMC Instruments software, calibration and service pathAEMC Instruments · software

DataView, USB, Ethernet, Wi-Fi and remote application paths support setup, live values and reports, subject to compatible firmware, operating system, permissions and network policy AEMC's U.S. lab supports repair and calibration; the analyzer and three sensors need exact scope, interval and serial retention

Source type
support
Content hash
55b6e862993cfff4
Use
store excerpt
Open AEMC Instruments
05
Qualified electrical work and hazard-control boundaryOSHA · specification

Electrical work around exposed energized parts requires qualified-person boundaries, de-energization where feasible, hazard assessment and appropriate practices and protective equipment. An analyzer does not authorize live work.

Source type
support
Content hash
bb02fba2730aa8f5
Use
store excerpt
Open OSHA
06
Portable power logger voltage-lead hazard evidenceFluke safety notice · consensus

Fluke's critical alert for 173x and 174x voltage leads demonstrates that the complete lead set, connection sequence and current safety-notice state must be checked for every brand and deployment; a CAT label alone is insufficient.

Source type
editorial
Content hash
4c7366b1593d18d8
Use
store excerpt
Open Fluke safety notice
07
AEMC PEL 113 independent professional-market coverageTEquipment · specification

Independent professional coverage examines the exact product or closest retained family system for field setup, package, controls, data, software or ownership. It cannot establish performance for another configuration, sensor, circuit, trigger, firmware or operator.

Source type
editorial
Content hash
1198e9e24fe0c07a
Use
store excerpt
Open TEquipment
08
PEL 113 Power and Energy Logger current operator discussionsPower-quality technicians and electrical professionals · consensus

Self-selected operators discuss lcd value, sensor range, phase adapter, dataview setup, alarms, long files, battery and pel 103 migration. Reports span different circuits, sensors, firmware, thresholds, intervals, software, calibration states and skill and cannot establish accuracy, safety or failure rates.

Source type
community
Content hash
b664a2d2d9dbd8c0
Use
store excerpt
Open Power-quality technicians and electrical professionals
09
PEL 112 Power and Energy Logger comparison alternativeAEMC Instruments · alternative

PEL 112 Power and Energy Logger represents the low-cost displayless energy logging branch at $2,675 current AEMC U.S. list-price boundary.

Source type
manufacturer
Content hash
44b088199bc3ab63
Use
store excerpt
Open AEMC Instruments
10
1736/EUS Three-Phase Power Logger comparison alternativeFluke · alternative

1736/EUS Three-Phase Power Logger represents the general load and energy studies with power-quality trends branch at $6,874.22 current authorized U.S. street reference.

Source type
manufacturer
Content hash
b0621e35f8c9d396
Use
store excerpt
Open Fluke

Manufacturer identity, specifications, manual or support, current U.S. price or list-price boundary, independent professional coverage, bounded operator discussion and U.S. calibration or service were checked on August 18, 2026. This desk covers complete current or currently supported portable professional power-quality analyzers and loggers that measure and time-record power-quality parameters for qualified electrical work. It excludes ordinary multimeters and clamp meters, basic plug-in monitors, benchtop oscilloscopes, protective relays, permanent panel meters, bare sensors, obsolete systems and cosmetic or service bundles counted as products. Preserve exact standards class and edition; line topology; voltage and current inputs; CAT and input limits; sensor type, range, bandwidth, orientation and connector; event, waveform, transient, harmonic, interharmonic, flicker and aggregation behavior; time synchronization; storage; software, firmware, licenses, cloud and export; battery, phase power, ingress state, mounting, calibration, service and safety-alert status. No reading, event, standard, report, review or owner account establishes root cause, code compliance, safe work, equipment health, utility responsibility or a guaranteed outcome.

Researching another model?

Search the current market