Current price
Confirm the exact base or Aluminum One-Pak, facility voltage, gun type, TIG kit and current rebate. Confirm the checkout price and package before paying.
Lincoln Electric · K5376-1
Ready to buy
The retained reference is $4,579 current independent U.S. K5376-1 reference. Confirm the exact base or Aluminum One-Pak, facility voltage, gun type, TIG kit and current rebate. Confirm the current configuration, included parts, support path, return terms and the work that must be preserved before ordering.
Current market
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
Confirm the exact base or Aluminum One-Pak, facility voltage, gun type, TIG kit and current rebate. Confirm the checkout price and package before paying.
Choose the 262MP for a fixed or cart-based shop that will use pulsed MIG, 12-inch spools and higher duty-cycle work and does not need AC TIG.
Other paths
These are not generic competitors. Each one represents a different way to buy into the same market.
Miller Electric
ESAB
What changed
Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.
POWER MIG 262MP was checked against its manufacturer record, the current category collection and the nearest ownership alternatives.
Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.
Current reference priceA structured timeline will begin with the next source capture
Owner experience
Owner discussion repeatedly returns to 250-pound mobility, pulse-mig setup, push versus push-pull package, input voltage, display workflow and service rather than specifications alone.
These are self-reported experiences from a changing mix of owners, conditions and software versions. They identify questions to test, not a failure rate. Skill, procedure, input circuit, material, consumable, shielding gas, joint, environment, ventilation, maintenance and local service vary materially.Actual owners compare 262MP and 255 price, mobility and shop fit. Their bounded reports identify decision questions rather than reliability or output rates.
Owner comparisons clarify mobility and package cost but do not prove better arc behavior or uptime across shops.
1 evidence recordSources
The page separates what a source states directly from what we conclude across sources.
Lincoln Electric identifies POWER MIG 262MP as a 250-pound single-phase shop machine with MIG, pulsed MIG, flux-core, stick, DC TIG and pulsed DC TIG plus a seven-inch interface
Cyberweld lists K5376-1 at $4,579 before the observed rebate and distinguishes separate push and push-pull aluminum One-Paks.
Lincoln Electric publishes setup, compatibility or service material that makes this purchase boundary explicit: K5376-1 is the standard machine rather than an aluminum push or push-pull One-Pak; cart-integrated weight, input circuit, TIG hardware, gas and fume control must be planned. Arc welding can cause fatal electric shock, arc-flash and ultraviolet eye or skin injury, burns, fire or explosion, compressed-gas injury and hazardous fume exposure. A qualified electrician must size the receptacle, branch circuit, grounding, disconnect, extension lead and generator from the exact rating label and manual; 120/240 V capability is not permission to use an adapter or undersized circuit. Inspect leads and insulation, keep the work area and operator dry, de-energize before service and use the exact manual's lockout and discharge procedure. Select helmet shade, eye, face, hearing, hand, body and respiratory protection from the actual process, current, task and hazard assessment, and screen bystanders from the arc. Identify base metal, coatings, filler, flux, cleaners and SDS hazards; keep the head out of the plume and use effective local exhaust or a formal respiratory program where required. Outdoor or open-door work does not prove adequate ventilation, and oxygen must never be used for ventilation. Remove or protect combustibles, inspect concealed spaces and use the required hot-work permit and fire watch. Secure cylinders upright, protect valves and use the correct gas, regulator, hose and leak test. Implanted-device users must consult the device maker and clinician and follow the machine manual's EMF cable-routing guidance; no universal safe distance is asserted. Presets, synergic programs, pulse modes and software do not qualify an operator, welding procedure, code weld, structural repair or safety-critical repair. Duty cycle and output are process-, voltage-, phase- and temperature-specific, so maximum amperage alone is not a performance ranking.
The current U.S. dealer market distinguishes machine-only SKUs from TIG, cart, educational, spool-gun and push-pull packages and publishes current prices before rebates, tax and separately purchased safety systems.
The independent dealer overview examines the 262MP's display, process and package choices; published ratings remain tied to Lincoln's exact specification.
OSHA identifies metal fumes, UV radiation, burns, eye damage, electrical shock and fire among welding hazards; NIOSH states that plume composition and exposure vary with process, consumable, base metal and coatings and supports effective ventilation controls.
Actual owners compare 262MP and 255 price, mobility and shop fit. Their bounded reports identify decision questions rather than reliability or output rates.
Multimatic 255 represents the higher-output pulse-mig fabrication platform branch at $4,777 current independent U.S. machine reference.
Rebel EMP 235ic represents the higher-output portable smig fabrication machine branch at $3,314.35 current independent U.S. exact-model reference.
The manufacturer record, current market collection, support material and independent category evidence were checked on August 17, 2026. The checkout package and regional support path still need verification. Owner reports are retained as bounded experience, not a reliability rate. Arc welding can cause fatal electric shock, arc-flash and ultraviolet eye or skin injury, burns, fire or explosion, compressed-gas injury and hazardous fume exposure. A qualified electrician must size the receptacle, branch circuit, grounding, disconnect, extension lead and generator from the exact rating label and manual; 120/240 V capability is not permission to use an adapter or undersized circuit. Inspect leads and insulation, keep the work area and operator dry, de-energize before service and use the exact manual's lockout and discharge procedure. Select helmet shade, eye, face, hearing, hand, body and respiratory protection from the actual process, current, task and hazard assessment, and screen bystanders from the arc. Identify base metal, coatings, filler, flux, cleaners and SDS hazards; keep the head out of the plume and use effective local exhaust or a formal respiratory program where required. Outdoor or open-door work does not prove adequate ventilation, and oxygen must never be used for ventilation. Remove or protect combustibles, inspect concealed spaces and use the required hot-work permit and fire watch. Secure cylinders upright, protect valves and use the correct gas, regulator, hose and leak test. Implanted-device users must consult the device maker and clinician and follow the machine manual's EMF cable-routing guidance; no universal safe distance is asserted. Presets, synergic programs, pulse modes and software do not qualify an operator, welding procedure, code weld, structural repair or safety-critical repair. Duty cycle and output are process-, voltage-, phase- and temperature-specific, so maximum amperage alone is not a performance ranking. AC TIG and aluminum MIG through a spool or push-pull gun are different process paths. Pulse is always identified as pulsed MIG, pulsed DC TIG, pulsed AC TIG, double-pulsed MIG or pulsed stick where applicable. No record promises universal penetration, bead appearance, receiver-like rankings from maximum amps, code acceptance, procedure qualification, reliability incidence or a safe circuit without label-based installation.
Researching another model?