Market IndexProduct intelligenceDigital oscilloscopesSearch products
All marketsProfessional digital oscilloscopesTektronix

Tektronix · MSO44B with 4-BW-200

4 Series B MSO44B 200 MHz

A 12-bit four-FlexChannel 200 MHz scope with a 13.3-inch touch display, 6.25 GS/s acquisition and a broad licensed analysis ecosystem
Market statusCurrent four-FlexChannel 200 MHz bench scopeChecked Aug 18
Reference price$10,800 current U.S. base priceTektronix U.S. starting price for MSO44B with 200 MHz bandwidth
Product cyclecurrentRelease history under review
EvidenceWell supported5 publishers · 2 independent
Next full checkAug 25, 2026Price checks run sooner
01

Ready to buy

Quote the instrument, licenses, probes and calibration

The retained reference is $10,800 current U.S. base price. Confirm the 4-BW-200 license, 31.25 or 62.5 Mpoint state, TLP058 count, serial packages, analysis applications, probes and service coverage. Reproduce the intended four-channel capture, trigger, decode, export and reference condition inside the return window.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$10,800 current U.S. base price

Confirm the 4-BW-200 license, 31.25 or 62.5 Mpoint state, TLP058 count, serial packages, analysis applications, probes and service coverage. Confirm current checkout or written-quote pricing before paying.

Refresh due soonDirect source1 evidence item

Market branch

High-resolution mixed-signal bench debug
Checked 6 days agoOur synthesis2 evidence items

Exact purchase boundary

Each FlexChannel is one analog channel or eight digital inputs with an optional TLP058, so the headline digital count trades away analog channels; 200 MHz and 31.25 Mpoints are the retained base state
Checked 6 days agoOur synthesis4 evidence items

Channels, bandwidth and upgrade state

Four FlexChannel inputs at 200 MHz; each accepts one analog signal or, with a separately purchased TLP058, eight digital signals, and later 350 MHz through 1.5 GHz upgrades require licensed hardware support
Checked 6 days agoDirect source2 evidence items

Sample rate, memory and segmentation

All four inputs can sample at 6.25 GS/s; standard record length is 31.25 Mpoints per channel with an optional 62.5 Mpoint state, and quoted FastAcq rates depend on acquisition mode and displayed record
Checked 6 days agoDirect source2 evidence items

ADC, resolution and noise boundary

A 12-bit ADC operates across the stated sample rates; Hi Res processing can increase displayed resolution toward 16 bits only by reducing effective bandwidth, and neither bit count establishes ENOB or noise on every range
Checked 6 days agoOur synthesis2 evidence items

Acquisition, update rate and trigger

Visual, edge, pulse, logic, sequence and bus triggers plus segmented or fast acquisition are available by mode and license; trigger-rate and waveform-rate claims are conditional rather than simultaneous maxima
Checked 6 days agoOur synthesis2 evidence items

Decode, math and licenses

Protocol decode, spectrum view, jitter, power, compliance and other analysis are application licenses; digital acquisition also requires a TLP058 and consumes the selected FlexChannel
Checked 6 days agoDirect source3 evidence items

Display, export and connectivity

The 13.3-inch 1920 by 1080 touch display supports USB, LAN, remote browser control, TekScope and TekDrive-compatible export paths; software versions, accounts and network policy govern remote or cloud use
Checked 6 days agoDirect source2 evidence items

Included probes and loading

The standard 200 MHz configuration includes one TPP0250 250 MHz 10:1 passive probe per FlexChannel; it does not include a TLP058 logic probe or a differential, current or high-voltage probe
Checked 6 days agoDirect source3 evidence items

Input, voltage and reference boundary

Analog channels are common-reference, earth-referenced inputs rather than isolated inputs; passive-probe and BNC voltage, frequency, 1 MΩ or 50 Ω termination and grounding limits all apply
Checked 6 days agoOur synthesis2 evidence items

Power, calibration and service

AC-powered bench operation, a calibration certificate and published firmware and service routes are standard boundaries; accredited calibration, extended warranty, loaners and downtime protection are separately quoted
Checked 6 days agoDirect source2 evidence items

Outcome boundary

No bandwidth, sample-rate, memory, ADC, noise, trigger, decode, update-rate, isolation or measurement-category specification and no review or owner report guarantees signal integrity, a diagnosis, debugging success, electrical safety, uptime, reliability or a professional outcome for a different configuration, probe, circuit, firmware, environment or operator.
Checked 6 days agoOur synthesis4 evidence items

Current verdict

The compact FlexChannel lab platform

The MSO44B fits teams that want Tektronix 12-bit acquisition and a large touch canvas in four channels and can budget separately for logic probes, bandwidth, record length and application licenses.

Checked 6 days agoOur synthesis8 evidence items
03

Other paths

The alternatives change what the 4 Series B MSO44B 200 MHz is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01lower upfront

Rohde & Schwarz

MXO 4 MXO44 200 MHz

$10,790 current U.S. configured price
Best fit
High-update low-noise embedded and power debug
Tradeoff
MXO44-242 fixes the retained state at 200 MHz; mixed-signal, generator, protocol, power, spectrum and higher-bandwidth capabilities depend on ordered hardware or licenses
Open the source
02lower upfront

Keysight

InfiniiVision HD304MSO 200 MHz

$8,232.64 current U.S. configured price
Best fit
Low-noise embedded and power bench debug
Tradeoff
The retained 200 MHz HD304MSO has 20 Mpoints per channel standard; advertised 100 Mpoint states, waveform-generator functions, advanced bus packages and higher bandwidths require exact configuration checks
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current configuration, price and support position retained

    4 Series B MSO44B 200 MHz was checked against exact manufacturer specifications and operating material, a current U.S. price, current support, product-specific independent coverage and bounded owner evidence.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $10,800 current U.S. base price

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Owner discussion repeatedly returns to flexchannel tradeoffs, touch-first controls, option licensing, update-rate modes, probe ecosystem cost and remote analysis rather than a brand or specification rank.

These are self-reported experiences from different samples, firmware versions, options, probes, circuits, environments and skill levels. They identify tests to run and do not establish signal integrity, measurement accuracy, diagnosis, debugging success, electrical safety, battery endurance, reliability, failure rates or professional outcomes.
SignalWhat owners reportOur readEvidence

FlexChannel tradeoffs, touch-first controls, option licensing, update-rate modes, probe ecosystem cost and remote analysis

Owners discuss flexchannel tradeoffs, touch-first controls, option licensing, update-rate modes, probe ecosystem cost and remote analysis with mixed configurations and outcomes.

Map every required analog and digital signal to a FlexChannel and price all probes and licenses before comparing it with fixed analog-plus-digital architectures.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
4 Series B MSO44B 200 MHz official product identityTektronix · identity

Tektronix identifies 4 Series B MSO44B 200 MHz, model MSO44B with 4-BW-200, as a 12-bit four-FlexChannel 200 MHz scope with a 13.3-inch touch display, 6.25 GS/s acquisition and a broad licensed analysis ecosystem. Four FlexChannel inputs at 200 MHz; each accepts one analog signal or, with a separately purchased TLP058, eight digital signals, and later 350 MHz through 1.5 GHz upgrades require licensed hardware support

Source type
manufacturer
Content hash
542492bfb3dbd2dd
Use
store excerpt
Open Tektronix
02
4 Series B MSO44B 200 MHz current U.S. priceTektronix · price

$10,800 current U.S. base price was retained from the exact current U.S. product or configured listing. Confirm the 4-BW-200 license, 31.25 or 62.5 Mpoint state, TLP058 count, serial packages, analysis applications, probes and service coverage

Source type
manufacturer
Content hash
a547b317f29c56c0
Use
store snapshot
Open Tektronix
03
4 Series B MSO44B 200 MHz official specification and operating manualTektronix · specification

All four inputs can sample at 6.25 GS/s; standard record length is 31.25 Mpoints per channel with an optional 62.5 Mpoint state, and quoted FastAcq rates depend on acquisition mode and displayed record A 12-bit ADC operates across the stated sample rates; Hi Res processing can increase displayed resolution toward 16 bits only by reducing effective bandwidth, and neither bit count establishes ENOB or noise on every range Visual, edge, pulse, logic, sequence and bus triggers plus segmented or fast acquisition are available by mode and license; trigger-rate and waveform-rate claims are conditional rather than simultaneous maxima The standard 200 MHz configuration includes one TPP0250 250 MHz 10:1 passive probe per FlexChannel; it does not include a TLP058 logic probe or a differential, current or high-voltage probe Analog channels are common-reference, earth-referenced inputs rather than isolated inputs; passive-probe and BNC voltage, frequency, 1 MΩ or 50 Ω termination and grounding limits all apply

Source type
support
Content hash
6f0783a441e83e19
Use
store excerpt
Open Tektronix
04
4 Series B MSO44B 200 MHz official firmware, calibration and support pathTektronix · software

Protocol decode, spectrum view, jitter, power, compliance and other analysis are application licenses; digital acquisition also requires a TLP058 and consumes the selected FlexChannel The 13.3-inch 1920 by 1080 touch display supports USB, LAN, remote browser control, TekScope and TekDrive-compatible export paths; software versions, accounts and network policy govern remote or cloud use AC-powered bench operation, a calibration certificate and published firmware and service routes are standard boundaries; accredited calibration, extended warranty, loaners and downtime protection are separately quoted

Source type
support
Content hash
0423e59a7b21bad1
Use
store excerpt
Open Tektronix
05
Tektronix 4 Series B independent product tryoutTest & Measurement Tips · specification

Product-specific independent coverage examines 4 Series B MSO44B 200 MHz acquisition, interface, probing or workflow behavior under a bounded test configuration. It does not establish a result for another sample, firmware, probe, circuit or operator.

Source type
editorial
Content hash
f37a2cda416e727c
Use
store excerpt
Open Test & Measurement Tips
06
4 Series B MSO44B 200 MHz current owner discussionsOscilloscope owners · consensus

Self-selected owners discuss flexchannel tradeoffs, touch-first controls, option licensing, update-rate modes, probe ecosystem cost and remote analysis. Reports vary by instrument sample, firmware, options, probes, circuit, environment and experience and do not establish a success, safety or reliability rate.

Source type
community
Content hash
060a6e0821d19a5a
Use
store excerpt
Open Oscilloscope owners
07
MXO 4 MXO44 200 MHz comparison alternativeRohde & Schwarz · alternative

MXO 4 MXO44 200 MHz represents the high-update low-noise embedded and power debug branch at $10,790 current U.S. configured price.

Source type
manufacturer
Content hash
a09a165126a923e4
Use
store excerpt
Open Rohde & Schwarz
08
InfiniiVision HD304MSO 200 MHz comparison alternativeKeysight · alternative

InfiniiVision HD304MSO 200 MHz represents the low-noise embedded and power bench debug branch at $8,232.64 current U.S. configured price.

Source type
manufacturer
Content hash
92e4496f8b920075
Use
store excerpt
Open Keysight

Manufacturer identity, specifications, manuals and support, a current U.S. exact-model or exact-configuration price, product-specific independent coverage and bounded owner discussion were checked on August 18, 2026. This desk covers complete, currently supported bench and isolated or portable digital oscilloscopes for professional electronics, embedded, power, automotive and serious laboratory work. It excludes toy or USB-only hobby gadgets without supported front-end specifications, logic analyzers or spectrum analyzers as the primary instrument, unsupported models, cosmetic bundles and probe or software kits counted as instruments. Channel count, bandwidth and upgrade state, sample rate by active channel, memory, segmentation, update rate, ADC modes, noise, trigger, decode, math, display, connectivity, cloud, included probes, input voltage, CAT rating, ground reference, isolation, battery, calibration and service remain configuration and condition dependent. No specification, review or owner report guarantees signal integrity, a diagnosis, debugging success, electrical safety, reliability or a professional outcome. Confirm the exact model, options, probes, loading, voltage and measurement category, grounding, firmware, seller, warranty, calibration and return rights before use.

Researching another model?

Search the current market