Current price
Confirm 200 MHz, standard versus 500 Mpoint memory, four PVP2350 probes, digital pod, generator, decoder packages, firmware and calibration certificate. Confirm current checkout or written-quote pricing before paying.
Rigol · DHO4204
Ready to buy
The retained reference is $2,829 current U.S. price. Confirm 200 MHz, standard versus 500 Mpoint memory, four PVP2350 probes, digital pod, generator, decoder packages, firmware and calibration certificate. Reproduce the intended four-channel capture, trigger, decode, export and reference condition inside the return window.
Current market
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
Confirm 200 MHz, standard versus 500 Mpoint memory, four PVP2350 probes, digital pod, generator, decoder packages, firmware and calibration certificate. Confirm current checkout or written-quote pricing before paying.
DHO4204 is a strong price-to-depth choice for four-channel 12-bit work when the team can validate firmware, licensed analysis and all-channel acquisition conditions.
Other paths
These are not generic competitors. Each one represents a different way to buy into the same market.
Keysight
Siglent
What changed
Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.
DHO4204 was checked against exact manufacturer specifications and operating material, a current U.S. price, current support, product-specific independent coverage and bounded owner evidence.
Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.
Current reference priceA structured timeline will begin with the next source capture
Owner experience
Owner discussion repeatedly returns to very deep records, all-channel rate, 12-bit noise, ultraacquire modes, firmware updates, fan profile and application licensing rather than a brand or specification rank.
These are self-reported experiences from different samples, firmware versions, options, probes, circuits, environments and skill levels. They identify tests to run and do not establish signal integrity, measurement accuracy, diagnosis, debugging success, electrical safety, battery endurance, reliability, failure rates or professional outcomes.Owners discuss very deep records, all-channel rate, 12-bit noise, ultraacquire modes, firmware updates, fan profile and application licensing with mixed configurations and outcomes.
Capture the intended four-channel event at full depth, then search, measure and export it on the current firmware before treating memory capacity as usable workflow speed.
1 evidence recordSources
The page separates what a source states directly from what we conclude across sources.
Rigol identifies DHO4204, model DHO4204, as a four-channel 200 MHz 12-bit bench scope with 4 GS/s peak acquisition, 250 Mpoint standard maximum memory and a 10.1-inch touch display. Four analog channels at 200 MHz; higher DHO4000 bandwidth models are separate instruments and mixed-signal acquisition needs optional logic hardware
$2,829 current U.S. price was retained from the exact current U.S. product or configured listing. Confirm 200 MHz, standard versus 500 Mpoint memory, four PVP2350 probes, digital pod, generator, decoder packages, firmware and calibration certificate
Maximum acquisition is 4 GS/s with one channel, 2 GS/s with two and 1 GS/s with all four; standard maximum memory is 250 Mpoints with a 500 Mpoint option, while segmentation and all-channel depth depend on selected acquisition settings A 12-bit ADC is native; high-resolution filters and bandwidth limits can reduce visible noise by sacrificing bandwidth, with no universal ENOB implied Edge, pulse, runt, logic, setup or hold, serial and zone tools combine with segmented memory; normal waveform rates around 50,000 and UltraAcquire claims up to 1.5 million require different conditions Four PVP2350 probes are standard, each 350 MHz at 10:1 with about 10 MΩ and 10 pF and 35 MHz at 1:1 with about 1 MΩ and 50 pF The analog channels share an earth reference and are not isolated; PVP2350 CAT II limits, frequency derating, BNC termination and the circuit reference govern safe use
Protocol decode, 16 digital channels, arbitrary generation, power analysis and advanced applications depend on ordered options and probes The 10.1-inch touch display supports USB, LAN, HDMI, remote control, screen and waveform export; account or cloud storage belongs to any external service, not basic local use AC bench power, firmware downloads and Rigol calibration or repair paths are available; accredited results, calibration interval, loaners and turnaround depend on the service order
Product-specific independent coverage examines DHO4204 acquisition, interface, probing or workflow behavior under a bounded test configuration. It does not establish a result for another sample, firmware, probe, circuit or operator.
Self-selected owners discuss very deep records, all-channel rate, 12-bit noise, ultraacquire modes, firmware updates, fan profile and application licensing. Reports vary by instrument sample, firmware, options, probes, circuit, environment and experience and do not establish a success, safety or reliability rate.
InfiniiVision HD304MSO 200 MHz represents the low-noise embedded and power bench debug branch at $8,232.64 current U.S. configured price.
SDS2104X Plus represents the upgradeable mainstream embedded and mixed-signal bench branch at $1,399 current U.S. price.
Manufacturer identity, specifications, manuals and support, a current U.S. exact-model or exact-configuration price, product-specific independent coverage and bounded owner discussion were checked on August 18, 2026. This desk covers complete, currently supported bench and isolated or portable digital oscilloscopes for professional electronics, embedded, power, automotive and serious laboratory work. It excludes toy or USB-only hobby gadgets without supported front-end specifications, logic analyzers or spectrum analyzers as the primary instrument, unsupported models, cosmetic bundles and probe or software kits counted as instruments. Channel count, bandwidth and upgrade state, sample rate by active channel, memory, segmentation, update rate, ADC modes, noise, trigger, decode, math, display, connectivity, cloud, included probes, input voltage, CAT rating, ground reference, isolation, battery, calibration and service remain configuration and condition dependent. No specification, review or owner report guarantees signal integrity, a diagnosis, debugging success, electrical safety, reliability or a professional outcome. Confirm the exact model, options, probes, loading, voltage and measurement category, grounding, firmware, seller, warranty, calibration and return rights before use.
Researching another model?