Market IndexProduct intelligenceDigital multimetersSearch products
All marketsProfessional digital multimetersKeysight

Keysight · U1282A

U1282A

A 60,000-count industrial handheld with 0.025% basic DC accuracy, IP67 construction, up to 800-hour published battery life, filtering, ZLow, PWM measurement and internal logging
Market statusCurrent IP67 60,000-count long-runtime logging multimeterChecked Aug 17
Reference price$947 current U.S. list referenceCurrent Keysight and authorized-channel U.S. reference for the U1282A
Product cyclecurrentRelease history under review
EvidenceWell supported8 publishers · 3 independent
Next full checkAug 24, 2026Price checks run sooner
01

Ready to buy

Confirm the meter, leads, fuses and calibration

The retained reference is $947 current U.S. list reference. Confirm exact U1282A, calibration certificate, U1173B or U1117A interface need, lead kit, stock and KeysightCare territory before ordering. Verify the exact package and category markings, inspect every input, prove operation on known sources and document calibration status before field use.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$947 current U.S. list reference

Confirm exact U1282A, calibration certificate, U1173B or U1117A interface need, lead kit, stock and KeysightCare territory before ordering. Confirm current checkout or quoted price, seller authorization, calibration option and return rights before paying.

Refresh due after 7 daysDirect source1 evidence item

Market branch

High-resolution long-duration industrial field logging
Checked 7 days agoOur synthesis2 evidence items

Purchase boundary

Its high count, long battery claim and IP67 body do not validate a waveform, unattended live connection, seal condition or computer workflow; each depends on range, environment, accessory and procedure
Checked 7 days agoOur synthesis4 evidence items

Category, inputs and protection

CAT III 1000 V and CAT IV 600 V apply to marked inputs with specified leads, shutters, fuses and the closed intact enclosure; IP67 is a dust/water test, not an energized wet-work authorization
Checked 7 days agoOur synthesis4 evidence items

Display, accuracy and conditions

The 4.5-digit 60,000-count dual display and 0.025% basic DC accuracy are subject to one-year calibration, range, temperature and counts; 250 ppm is not the uncertainty of every function
Checked 7 days agoDirect source3 evidence items

True RMS, bandwidth and filters

True RMS AC, low-pass and PWM-related modes have explicit bandwidth, crest-factor, duty, amplitude and coupling limits; the function choice must be retained with each result
Checked 7 days agoOur synthesis2 evidence items

Ranges and measurement functions

Measures to 1000 V and 10 A, resistance, capacitance, frequency, diode, continuity and temperature, with U1282A additions including harmonic ratio, low-pass, ZLow and square-wave output
Checked 7 days agoDirect source2 evidence items

Continuity, LoZ and test energy

ZLow reduces ghost voltage and Smart Ohm or continuity aids fault work; source loading, threshold and open-circuit test voltage can affect electronics
Checked 7 days agoOur synthesis3 evidence items

Logging and connectivity

Internal manual, interval and event logging can retain readings, while isolated PC or Bluetooth transfer requires the exact optional adapter, current software and a supported operating system
Checked 7 days agoOur synthesis3 evidence items

Battery, fuses and replacement

Four AA cells support up to the maker's stated 800-hour condition; replace batteries and the exact high-energy fuses only with leads removed, the instrument de-energized and the seal procedure followed
Checked 7 days agoOur synthesis3 evidence items

Calibration and service

Keysight includes commercial calibration data and publishes calibration/service options; an accredited result, adjustment, uncertainty and pre/post data must be specified on the service order
Checked 7 days agoOur synthesis3 evidence items

Leads, probes and package

The standard package includes test leads, four AA batteries, certificate and documentation; alligator clips, thermocouples, interfaces and some protection accessories vary by configuration
Checked 7 days agoOur synthesis3 evidence items

Qualified-work and outcome boundary

A logger attached to a hazardous circuit requires qualified design, secured probes, access control, PPE and an approved unattended-work plan; no record guarantees equipment condition or worker safety
Checked 7 days agoOur synthesis4 evidence items

No safety or diagnosis guarantee

No CAT mark, specification, calibration record, review, app or owner report guarantees safe work, correct PPE, compatibility, accuracy on a different signal, equipment diagnosis, repair outcome or absence of voltage. Follow the exact manual and the employer's qualified-person electrical-safety program.
Checked 7 days agoOur synthesis5 evidence items

Current verdict

The long-runtime precision field logger

U1282A is the defended alternative to a Fluke 289 when long AA runtime, IP67, 60,000 counts and PWM or filter tools matter, after verifying software, optical adapter and regional calibration support.

Checked 7 days agoOur synthesis9 evidence items
03

Other paths

The alternatives change what the U1282A is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01lower upfront

Fluke

289 True RMS Logging Multimeter

$839.99 current U.S. street reference
Best fit
Long-duration logging and intermittent industrial faults
Tradeoff
A saved trend is only as valid as the selected range, sample interval, trigger, leads, circuit state and clock, and the optional computer or wireless accessory path must not be assumed from the meter alone
Open the source
02ownership

Hioki

DT4282

$634 current U.S. authorized price
Best fit
High-accuracy lab and industrial field measurement
Tradeoff
The wide 20 Hz to 100 kHz AC voltage characteristic, five digits and 10 A jack each have range, signal, crest and duration limits, and optional USB does not create standalone logging
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact-meter evidence retained

    U1282A was checked against current manufacturer identity and support, a U.S. price path, calibration or service, product-specific independent coverage and bounded owner evidence.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $947 current U.S. list reference

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Owner discussion is retained as a checklist for autoranging speed, firmware, long battery claim, optical adapters, app support, seal care, fuse sourcing and calibration service, not as a safety, accuracy, reliability or failure rate.

These self-selected reports span different serials, ages, circuits, signals, environments, leads, fuses, calibration states, software and operator skill. They cannot prove that another meter is accurate, suitable or safe.
SignalWhat owners reportOur readEvidence

autoranging speed, firmware, long battery claim, optical adapters, app support, seal care, fuse sourcing and calibration service

Owners report both successful use and friction involving autoranging speed, firmware, long battery claim, optical adapters, app support, seal care, fuse sourcing and calibration service.

Rehearse a full log and export, confirm the actual battery condition with the chosen modes and document interface and firmware versions before a long unattended capture.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
U1282A official product and specification recordKeysight · identity

Keysight identifies model U1282A as a 60,000-count industrial handheld with 0.025% basic DC accuracy, IP67 construction, up to 800-hour published battery life, filtering, ZLow, PWM measurement and internal logging. CAT III 1000 V and CAT IV 600 V apply to marked inputs with specified leads, shutters, fuses and the closed intact enclosure; IP67 is a dust/water test, not an energized wet-work authorization

Source type
manufacturer
Content hash
f780179a743e5df6
Use
store excerpt
Open Keysight
02
U1282A current U.S. price referenceAuthorized U.S. test-equipment market · price

$947 current U.S. list reference is retained for the exact model under the stated package and seller qualifications. Confirm exact U1282A, calibration certificate, U1173B or U1117A interface need, lead kit, stock and KeysightCare territory before ordering

Source type
retailer
Content hash
c30c771dca08958a
Use
store snapshot
Open Authorized U.S. test-equipment market
03
U1282A official manual and operating limitsKeysight · specification

True RMS AC, low-pass and PWM-related modes have explicit bandwidth, crest-factor, duty, amplitude and coupling limits; the function choice must be retained with each result Four AA cells support up to the maker's stated 800-hour condition; replace batteries and the exact high-energy fuses only with leads removed, the instrument de-energized and the seal procedure followed The standard package includes test leads, four AA batteries, certificate and documentation; alligator clips, thermocouples, interfaces and some protection accessories vary by configuration

Source type
support
Content hash
8c320ed504e3909f
Use
store excerpt
Open Keysight
04
Keysight calibration, warranty and service pathKeysight · specification

Keysight includes commercial calibration data and publishes calibration/service options; an accredited result, adjustment, uncertainty and pre/post data must be specified on the service order

Source type
support
Content hash
f70f2370f2ae0cc0
Use
store excerpt
Open Keysight
05
Electrical safety and qualified-person boundaryOSHA · specification

Electrical work around exposed energized parts requires hazard assessment, qualified-person boundaries, de-energization where feasible and appropriate work practices and protective equipment. A meter does not authorize or make live work safe.

Source type
support
Content hash
40cb1b34de05b9e1
Use
store excerpt
Open OSHA
06
Safe multimeter selection and use boundaryFluke education · consensus

Professional meter use requires the correct category-rated instrument and leads, inspected equipment, the right terminals and functions, intact fuses and a known-live verification process. These controls apply across brands without endorsing one model.

Source type
editorial
Content hash
f0ecff61186e2c42
Use
store excerpt
Open Fluke education
07
Keysight U1282A independent RoadTestIndependent test-equipment reviewer · specification

Product-specific coverage examines U1282A controls, functions, response, display, input protection or teardown and value under the reviewer's stated bench or field conditions. It cannot certify another sample or high-energy use.

Source type
editorial
Content hash
bea6998b71c5e00f
Use
store excerpt
Open Independent test-equipment reviewer
08
U1282A current owner discussionsMultimeter owners and technicians · consensus

Self-selected owners discuss autoranging speed, firmware, long battery claim, optical adapters, app support, seal care, fuse sourcing and calibration service. Reports span different samples, ages, calibration states, circuits, leads, fuses and skill levels and cannot establish safety, accuracy or failure rates.

Source type
community
Content hash
a7628cdb9e472174
Use
store excerpt
Open Multimeter owners and technicians
09
289 True RMS Logging Multimeter comparison alternativeFluke · alternative

289 True RMS Logging Multimeter represents the long-duration logging and intermittent industrial faults branch at $839.99 current U.S. street reference.

Source type
manufacturer
Content hash
e87a803eaeb28b14
Use
store excerpt
Open Fluke
10
DT4282 comparison alternativeHioki · alternative

DT4282 represents the high-accuracy lab and industrial field measurement branch at $634 current U.S. authorized price.

Source type
manufacturer
Content hash
6d8f951b1b40be7c
Use
store excerpt
Open Hioki

Manufacturer identity and specifications, model-level manual or support, a current U.S. price path, calibration or service access, product-specific independent review and bounded owner discussion were checked on August 17, 2026. This desk covers current or currently supported complete handheld and bench-portable digital multimeters for professional electrical, electronics, HVAC, automotive, industrial and serious lab or field use. Clamp meters as the primary instrument, basic consumer testers, standalone oscilloscopes, process calibrators, cosmetic bundles, used-only and unsupported models are excluded. CAT ratings apply only at the marked category and voltage with correct inputs, leads, probes, tip guards, fuses, procedures and environment. True RMS, bandwidth, crest factor, counts, accuracy, range, resolution, LoZ, low-pass, temperature, continuity, logging, software and battery claims remain conditional. No record authorizes hazardous live work, selects PPE, replaces a qualified person, diagnoses equipment or guarantees safety or outcome.

Researching another model?

Search the current market