The facts that change the ownership choice
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
Current price
$289.99 current U.S. street referenceConfirm included 80BK probe, standard or CAL package and whether the job also requires a separate clamp meter, manometer, combustion analyzer or rated clips. Confirm current checkout or quoted price, seller authorization, calibration option and return rights before paying.
Last checked 52 days agoDirect source1 evidence itemMarket branch
HVAC service, controls and flame-sensor work
Checked 52 days agoOur synthesis2 evidence itemsPurchase boundary
Microamps, temperature and LoZ support HVAC troubleshooting but do not establish combustion safety, refrigerant charge, a failed control or a repair; every conclusion still needs the equipment procedure and other measurements
Checked 52 days agoOur synthesis4 evidence itemsCategory, inputs and protection
The 116 is rated CAT III 600 V with the stated terminals and accessories; the microamp jack, temperature adapter and probe do not inherit a higher voltage category from the meter body
Checked 52 days agoOur synthesis4 evidence itemsDisplay, accuracy and conditions
The 6,000-count display and 0.5% basic DC voltage condition are paired with separate specifications for microamps, resistance, capacitance and temperature, including probe error
Checked 52 days agoDirect source3 evidence itemsTrue RMS, bandwidth and filters
True RMS voltage and current readings have frequency and crest boundaries; LoZ deliberately loads the circuit and should not be used where that loading can alter sensitive controls
Checked 52 days agoOur synthesis2 evidence itemsRanges and measurement functions
Measures AC/DC voltage to 600 V, DC microamps for flame sensors, resistance, capacitance, frequency and K-type temperature; direct 10 A current is not part of the 116 function set
Checked 52 days agoDirect source2 evidence itemsContinuity, LoZ and test energy
Auto-V LoZ, continuity, Min/Max/Average and relative modes help separate ghost voltage and intermittent behavior, but they are not equipment diagnostic algorithms
Checked 52 days agoOur synthesis3 evidence itemsLogging and connectivity
There is no standalone time-stamped logging or native app connection; temperature and microamp trends require another approved recorder
Checked 52 days agoOur synthesis3 evidence itemsBattery, fuses and replacement
A 9 V battery powers the meter; the exact input design and battery procedure in the shared safety sheet must be followed with all leads removed before opening
Checked 52 days agoOur synthesis3 evidence itemsCalibration and service
The shared calibration manual covers voltage, resistance, capacitance, frequency, temperature and microamp verification; calibration and 80BK probe status should be retained separately
Checked 52 days agoOur synthesis3 evidence itemsLeads, probes and package
The standard kit includes test leads, 80BK integrated temperature probe, holster, installed battery and manual; probe temperature range, surface contact and electrical isolation remain separate limits
Checked 52 days agoOur synthesis3 evidence itemsQualified-work and outcome boundary
Only qualified HVAC/electrical personnel should apply readings to energized equipment, fuel-burning systems or controls, using manufacturer diagnostics, PPE and lockout; no meter reading guarantees a safe or correct repair
Checked 52 days agoOur synthesis4 evidence itemsNo safety or diagnosis guarantee
No CAT mark, specification, calibration record, review, app or owner report guarantees safe work, correct PPE, compatibility, accuracy on a different signal, equipment diagnosis, repair outcome or absence of voltage. Follow the exact manual and the employer's qualified-person electrical-safety program.
Checked 52 days agoOur synthesis5 evidence itemsCurrent verdict
The dedicated HVAC compact116 is the defended HVAC route when K-type temperature, DC microamps and LoZ are central and direct high-current measurement, logging or wider industrial category ratings are not.
Last checked 52 days agoOur synthesis9 evidence items