The facts that change the ownership choice
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
Current price
$289.99 current U.S. street referenceConfirm included 80BK probe, standard or CAL package and whether the job also requires a separate clamp meter, manometer, combustion analyzer or rated clips. Confirm current checkout or quoted price, seller authorization, calibration option and return rights before paying.
Refresh due after 7 daysDirect source1 evidence itemMarket branch
HVAC service, controls and flame-sensor work
Checked 7 days agoOur synthesis2 evidence itemsPurchase boundary
Microamps, temperature and LoZ support HVAC troubleshooting but do not establish combustion safety, refrigerant charge, a failed control or a repair; every conclusion still needs the equipment procedure and other measurements
Checked 7 days agoOur synthesis4 evidence itemsCategory, inputs and protection
The 116 is rated CAT III 600 V with the stated terminals and accessories; the microamp jack, temperature adapter and probe do not inherit a higher voltage category from the meter body
Checked 7 days agoOur synthesis4 evidence itemsDisplay, accuracy and conditions
The 6,000-count display and 0.5% basic DC voltage condition are paired with separate specifications for microamps, resistance, capacitance and temperature, including probe error
Checked 7 days agoDirect source3 evidence itemsTrue RMS, bandwidth and filters
True RMS voltage and current readings have frequency and crest boundaries; LoZ deliberately loads the circuit and should not be used where that loading can alter sensitive controls
Checked 7 days agoOur synthesis2 evidence itemsRanges and measurement functions
Measures AC/DC voltage to 600 V, DC microamps for flame sensors, resistance, capacitance, frequency and K-type temperature; direct 10 A current is not part of the 116 function set
Checked 7 days agoDirect source2 evidence itemsContinuity, LoZ and test energy
Auto-V LoZ, continuity, Min/Max/Average and relative modes help separate ghost voltage and intermittent behavior, but they are not equipment diagnostic algorithms
Checked 7 days agoOur synthesis3 evidence itemsLogging and connectivity
There is no standalone time-stamped logging or native app connection; temperature and microamp trends require another approved recorder
Checked 7 days agoOur synthesis3 evidence itemsBattery, fuses and replacement
A 9 V battery powers the meter; the exact input design and battery procedure in the shared safety sheet must be followed with all leads removed before opening
Checked 7 days agoOur synthesis3 evidence itemsCalibration and service
The shared calibration manual covers voltage, resistance, capacitance, frequency, temperature and microamp verification; calibration and 80BK probe status should be retained separately
Checked 7 days agoOur synthesis3 evidence itemsLeads, probes and package
The standard kit includes test leads, 80BK integrated temperature probe, holster, installed battery and manual; probe temperature range, surface contact and electrical isolation remain separate limits
Checked 7 days agoOur synthesis3 evidence itemsQualified-work and outcome boundary
Only qualified HVAC/electrical personnel should apply readings to energized equipment, fuel-burning systems or controls, using manufacturer diagnostics, PPE and lockout; no meter reading guarantees a safe or correct repair
Checked 7 days agoOur synthesis4 evidence itemsNo safety or diagnosis guarantee
No CAT mark, specification, calibration record, review, app or owner report guarantees safe work, correct PPE, compatibility, accuracy on a different signal, equipment diagnosis, repair outcome or absence of voltage. Follow the exact manual and the employer's qualified-person electrical-safety program.
Checked 7 days agoOur synthesis5 evidence itemsCurrent verdict
The dedicated HVAC compact116 is the defended HVAC route when K-type temperature, DC microamps and LoZ are central and direct high-current measurement, logging or wider industrial category ratings are not.
Checked 7 days agoOur synthesis9 evidence items