Market IndexProduct intelligenceDigital multimetersSearch products
All marketsProfessional digital multimetersFluke

Fluke · 116

116 HVAC Multimeter

A 6,000-count HVAC-focused handheld with True RMS, temperature, flame-sensor microamps, capacitance, frequency and Auto-V LoZ
Market statusCurrent HVAC True RMS temperature and microamp multimeterChecked Aug 17
Reference price$289.99 current U.S. street referenceCurrent authorized U.S. reference for the standard Fluke 116 package
Product cyclecurrentRelease history under review
EvidenceWell supported7 publishers · 3 independent
Next full checkAug 24, 2026Price checks run sooner
01

Ready to buy

Confirm the meter, leads, fuses and calibration

The retained reference is $289.99 current U.S. street reference. Confirm included 80BK probe, standard or CAL package and whether the job also requires a separate clamp meter, manometer, combustion analyzer or rated clips. Verify the exact package and category markings, inspect every input, prove operation on known sources and document calibration status before field use.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$289.99 current U.S. street reference

Confirm included 80BK probe, standard or CAL package and whether the job also requires a separate clamp meter, manometer, combustion analyzer or rated clips. Confirm current checkout or quoted price, seller authorization, calibration option and return rights before paying.

Refresh due after 7 daysDirect source1 evidence item

Market branch

HVAC service, controls and flame-sensor work
Checked 7 days agoOur synthesis2 evidence items

Purchase boundary

Microamps, temperature and LoZ support HVAC troubleshooting but do not establish combustion safety, refrigerant charge, a failed control or a repair; every conclusion still needs the equipment procedure and other measurements
Checked 7 days agoOur synthesis4 evidence items

Category, inputs and protection

The 116 is rated CAT III 600 V with the stated terminals and accessories; the microamp jack, temperature adapter and probe do not inherit a higher voltage category from the meter body
Checked 7 days agoOur synthesis4 evidence items

Display, accuracy and conditions

The 6,000-count display and 0.5% basic DC voltage condition are paired with separate specifications for microamps, resistance, capacitance and temperature, including probe error
Checked 7 days agoDirect source3 evidence items

True RMS, bandwidth and filters

True RMS voltage and current readings have frequency and crest boundaries; LoZ deliberately loads the circuit and should not be used where that loading can alter sensitive controls
Checked 7 days agoOur synthesis2 evidence items

Ranges and measurement functions

Measures AC/DC voltage to 600 V, DC microamps for flame sensors, resistance, capacitance, frequency and K-type temperature; direct 10 A current is not part of the 116 function set
Checked 7 days agoDirect source2 evidence items

Continuity, LoZ and test energy

Auto-V LoZ, continuity, Min/Max/Average and relative modes help separate ghost voltage and intermittent behavior, but they are not equipment diagnostic algorithms
Checked 7 days agoOur synthesis3 evidence items

Logging and connectivity

There is no standalone time-stamped logging or native app connection; temperature and microamp trends require another approved recorder
Checked 7 days agoOur synthesis3 evidence items

Battery, fuses and replacement

A 9 V battery powers the meter; the exact input design and battery procedure in the shared safety sheet must be followed with all leads removed before opening
Checked 7 days agoOur synthesis3 evidence items

Calibration and service

The shared calibration manual covers voltage, resistance, capacitance, frequency, temperature and microamp verification; calibration and 80BK probe status should be retained separately
Checked 7 days agoOur synthesis3 evidence items

Leads, probes and package

The standard kit includes test leads, 80BK integrated temperature probe, holster, installed battery and manual; probe temperature range, surface contact and electrical isolation remain separate limits
Checked 7 days agoOur synthesis3 evidence items

Qualified-work and outcome boundary

Only qualified HVAC/electrical personnel should apply readings to energized equipment, fuel-burning systems or controls, using manufacturer diagnostics, PPE and lockout; no meter reading guarantees a safe or correct repair
Checked 7 days agoOur synthesis4 evidence items

No safety or diagnosis guarantee

No CAT mark, specification, calibration record, review, app or owner report guarantees safe work, correct PPE, compatibility, accuracy on a different signal, equipment diagnosis, repair outcome or absence of voltage. Follow the exact manual and the employer's qualified-person electrical-safety program.
Checked 7 days agoOur synthesis5 evidence items

Current verdict

The dedicated HVAC compact

116 is the defended HVAC route when K-type temperature, DC microamps and LoZ are central and direct high-current measurement, logging or wider industrial category ratings are not.

Checked 7 days agoOur synthesis9 evidence items
03

Other paths

The alternatives change what the 116 HVAC Multimeter is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01ownership

Fluke

117 Electrician's Multimeter

$294.99 current U.S. street reference
Best fit
Commercial electrical troubleshooting with LoZ
Tradeoff
VoltAlert and LoZ are screening and ghost-voltage tools with distance, field, impedance and circuit limits; neither replaces direct contact testing, a proving unit or an absence-of-voltage procedure
Open the source
02ownership

IDEAL

61-347

About $129 current U.S. retail reference
Best fit
Accessible electrical service with visible hazard cues
Tradeoff
Audible, illuminated and non-contact warnings are secondary indications with threshold and field limits; they do not prove absence of voltage, fuse integrity, category suitability or a safe circuit
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact-meter evidence retained

    116 HVAC Multimeter was checked against current manufacturer identity and support, a U.S. price path, calibration or service, product-specific independent coverage and bounded owner evidence.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $289.99 current U.S. street reference

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Owner discussion is retained as a checklist for flame-sensor microamps, k-type probe error, loz loading, capacitance speed, missing amp input and companion-tool needs, not as a safety, accuracy, reliability or failure rate.

These self-selected reports span different serials, ages, circuits, signals, environments, leads, fuses, calibration states, software and operator skill. They cannot prove that another meter is accurate, suitable or safe.
SignalWhat owners reportOur readEvidence

flame-sensor microamps, K-type probe error, LoZ loading, capacitance speed, missing amp input and companion-tool needs

Owners report both successful use and friction involving flame-sensor microamps, k-type probe error, loz loading, capacitance speed, missing amp input and companion-tool needs.

Verify the microamp and temperature channels with known references and perform the equipment maker's complete diagnostic sequence before replacing a control or declaring a system safe.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
116 HVAC Multimeter official product and specification recordFluke · identity

Fluke identifies model 116 as a 6,000-count HVAC-focused handheld with True RMS, temperature, flame-sensor microamps, capacitance, frequency and Auto-V LoZ. The 116 is rated CAT III 600 V with the stated terminals and accessories; the microamp jack, temperature adapter and probe do not inherit a higher voltage category from the meter body

Source type
manufacturer
Content hash
0bcc20600e1ff0d0
Use
store excerpt
Open Fluke
02
116 HVAC Multimeter current U.S. price referenceAuthorized U.S. test-equipment market · price

$289.99 current U.S. street reference is retained for the exact model under the stated package and seller qualifications. Confirm included 80BK probe, standard or CAL package and whether the job also requires a separate clamp meter, manometer, combustion analyzer or rated clips

Source type
retailer
Content hash
df2696779fa0b730
Use
store snapshot
Open Authorized U.S. test-equipment market
03
116 HVAC Multimeter official manual and operating limitsFluke · specification

True RMS voltage and current readings have frequency and crest boundaries; LoZ deliberately loads the circuit and should not be used where that loading can alter sensitive controls A 9 V battery powers the meter; the exact input design and battery procedure in the shared safety sheet must be followed with all leads removed before opening The standard kit includes test leads, 80BK integrated temperature probe, holster, installed battery and manual; probe temperature range, surface contact and electrical isolation remain separate limits

Source type
support
Content hash
68fa947c31de33a0
Use
store excerpt
Open Fluke
04
Fluke calibration, warranty and service pathFluke · specification

The shared calibration manual covers voltage, resistance, capacitance, frequency, temperature and microamp verification; calibration and 80BK probe status should be retained separately

Source type
support
Content hash
9a6988b68f9dceab
Use
store excerpt
Open Fluke
05
Electrical safety and qualified-person boundaryOSHA · specification

Electrical work around exposed energized parts requires hazard assessment, qualified-person boundaries, de-energization where feasible and appropriate work practices and protective equipment. A meter does not authorize or make live work safe.

Source type
support
Content hash
40cb1b34de05b9e1
Use
store excerpt
Open OSHA
06
Safe multimeter selection and use boundaryFluke education · consensus

Professional meter use requires the correct category-rated instrument and leads, inspected equipment, the right terminals and functions, intact fuses and a known-live verification process. These controls apply across brands without endorsing one model.

Source type
editorial
Content hash
f0ecff61186e2c42
Use
store excerpt
Open Fluke education
07
Fluke 116 independent reviewIndependent test-equipment reviewer · specification

Product-specific coverage examines 116 HVAC Multimeter controls, functions, response, display, input protection or teardown and value under the reviewer's stated bench or field conditions. It cannot certify another sample or high-energy use.

Source type
editorial
Content hash
f19104b31549299f
Use
store excerpt
Open Independent test-equipment reviewer
08
116 HVAC Multimeter current owner discussionsMultimeter owners and technicians · consensus

Self-selected owners discuss flame-sensor microamps, k-type probe error, loz loading, capacitance speed, missing amp input and companion-tool needs. Reports span different samples, ages, calibration states, circuits, leads, fuses and skill levels and cannot establish safety, accuracy or failure rates.

Source type
community
Content hash
345d28f204066c35
Use
store excerpt
Open Multimeter owners and technicians
09
117 Electrician's Multimeter comparison alternativeFluke · alternative

117 Electrician's Multimeter represents the commercial electrical troubleshooting with loz branch at $294.99 current U.S. street reference.

Source type
manufacturer
Content hash
3c9c11d3dd5069cd
Use
store excerpt
Open Fluke
10
61-347 comparison alternativeIDEAL · alternative

61-347 represents the accessible electrical service with visible hazard cues branch at About $129 current U.S. retail reference.

Source type
manufacturer
Content hash
f10767ab7c9c3bec
Use
store excerpt
Open IDEAL

Manufacturer identity and specifications, model-level manual or support, a current U.S. price path, calibration or service access, product-specific independent review and bounded owner discussion were checked on August 17, 2026. This desk covers current or currently supported complete handheld and bench-portable digital multimeters for professional electrical, electronics, HVAC, automotive, industrial and serious lab or field use. Clamp meters as the primary instrument, basic consumer testers, standalone oscilloscopes, process calibrators, cosmetic bundles, used-only and unsupported models are excluded. CAT ratings apply only at the marked category and voltage with correct inputs, leads, probes, tip guards, fuses, procedures and environment. True RMS, bandwidth, crest factor, counts, accuracy, range, resolution, LoZ, low-pass, temperature, continuity, logging, software and battery claims remain conditional. No record authorizes hazardous live work, selects PPE, replaces a qualified person, diagnoses equipment or guarantees safety or outcome.

Researching another model?

Search the current market