Market IndexProduct intelligenceSump pumps and backupsSearch products
All marketsPremium home sump-pump and backup systemsWayne Water Systems

Wayne Water Systems · WSS30VN

WSS30Vn Combination System

A drop-in 1/2 HP primary and 12 V backup pair with separate switches, shared discharge, charger and audible backup alarm
Market statusCurrent preassembled primary-plus-battery-backup combinationChecked Aug 18
Reference price$567.36 current U.S. retail referenceHome Depot exact WSS30VN reference before battery
Product cyclecurrentRelease history under review
EvidenceWell supported10 publishers · 6 independent
Next full checkAug 25, 2026Price checks run sooner
01

Ready to buy

Confirm the exact pump, package and installation

The retained reference is $567.36 current U.S. retail reference. Confirm the upgraded N model, battery and check-valve exclusions and return terms, then measure the basin at the switch and inlet elevations before ordering. Commission every pump, float, check valve, alarm and notification path before relying on the installation.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$567.36 current U.S. retail reference

Confirm the upgraded N model, battery and check-valve exclusions and return terms, then measure the basin at the switch and inlet elevations before ordering. Confirm exact current stock, seller authorization, tax, delivery, battery, valves, pipe, alarm, labor, permits and return terms before paying.

Refresh due soonDirect source1 evidence item

System branch

Value preassembled combination
Checked 6 days agoOur synthesis2 evidence items

Complete-purchase boundary

WSS30VN needs a wide 15-inch tapered or 16-inch straight basin, a separately purchased 75 Ah battery and an installer-supplied check valve; its audible alarm has no remote connection and both pumps share one discharge assembly
Checked 6 days agoOur synthesis4 evidence items

Head and flow boundary

The AC CDU800 side is rated 5,100 GPH at zero and 3,840 at 10 feet; the 12 V side is rated 2,700 at zero and 1,500 GPH at 10 feet, so outage capacity must be compared at the actual head
Checked 6 days agoOur synthesis2 evidence items

Basin fit and solids boundary

Wayne specifies at least a 15-inch tapered or 16-inch non-tapered pit and an assembly width near 14.875 inches; both pumps are groundwater sump pumps rather than sewage or debris pumps
Checked 6 days agoOur synthesis3 evidence items

Switch, check valve and discharge

The AC vertical float and separate backup reed float require free movement; the preassembled pumps share a 1-1/2-inch discharge and require an installer-supplied check valve above the junction, leaving the valve and outlet as common failure points
Checked 6 days agoOur synthesis3 evidence items

Power, battery and charger

The primary uses 120 V and the backup uses one separately purchased supported 12 V deep-cycle battery, with Wayne recommending WSB1275 75 Ah; charger status does not replace periodic capacity testing
Checked 6 days agoOur synthesis3 evidence items

Runtime, alarm and connection

Wayne's hours-of-protection language depends on battery, head and cycling; the controller sounds an audible alarm when backup runs and has no built-in Wi-Fi or cloud notification
Checked 6 days agoOur synthesis3 evidence items

Maintenance, access and service

Water-test both switches, remove AC power under observation, load-test battery, inspect charger lights, the shared check valve and exterior outlet and preserve room to pull the whole assembly for component replacement
Checked 6 days agoOur synthesis4 evidence items

Warranty and failure modes

Current warranty documentation gives three-year limited coverage for WSS30Vn; dead battery, charger or reed-switch fault, AC switch fault, missing or failed check valve, blocked shared discharge, freeze, overwhelming inflow and unheard local alarm remain
Checked 6 days agoOur synthesis3 evidence items

Shock, flood, mold, sewage and outcome boundary

This system cannot make energized or contaminated water safe, prevent groundwater or sewer backflow, remove mold, authorize confined-space entry, satisfy every electrical or plumbing code, permit or insurance requirement or guarantee flood prevention, runtime, notification, reliability, property protection, coverage or a claim outcome.
Checked 6 days agoOur synthesis5 evidence items

Current verdict

The tested value combination

WSS30VN is the strongest mainstream value when the basin accepts its broad footprint and local-only alarm is adequate.

Checked 6 days agoOur synthesis12 evidence items
03

Other paths

The alternatives change what the WSS30Vn Combination System is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01ownership

Zoeller Pump Company

Aquanot Fit 508 ProPak with M53

$1,033.50 current U.S. street reference
Best fit
Professional preassembled connected combination
Tradeoff
The drop-in assembly still requires a compatible basin, separate battery, code-compliant receptacle and discharge; one preassembled check valve and pipe do not remove shared-path or freeze risks
Open the source
02ownership

Glentronics

Basement Watchdog Big Combo CONNECT

$469.00 current U.S. retail reference
Best fit
Mainstream monitored combination
Tradeoff
CITS-50 is preassembled but the battery and BW-WiFi2 remote module are separate; its shared discharge, basin fit and controller generation must be confirmed
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact pump, package, price and failure boundary retained

    WSS30Vn Combination System was checked against exact manufacturer identity and manual, current U.S. price, hydraulic curve, basin and switch fit, discharge and check-valve path, power or battery system, alarm and connectivity, service, independent evidence and bounded owner or installer reports.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $567.36 current U.S. retail reference

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Owner and installer discussion returns to wide-basin fit, drop-in plumbing, check-valve addition, battery choice, local alarm and outage testing rather than a universal reliability or flood result.

These are self-reported experiences across different basins, inflows, heads, pipe and check-valve layouts, circuits, batteries, chargers, alarms, networks, maintenance, installation quality, weather and service ages. They identify commissioning and service checks and do not establish standardized flow, runtime, notification delivery, reliability, failure rate, flood prevention, mold prevention, safety, code approval, insurability or claim outcomes.
SignalWhat owners reportOur readEvidence

wide-basin fit, drop-in plumbing, check-valve addition, battery choice, local alarm and outage testing

Exact-model owners discuss quick installation, broad footprint, pump replacement access, alarm, battery purchase and outage operation. Reports cannot prove runtime or long-term reliability.

Build a cardboard footprint at the inlet and float heights, add the specified check valve and then prove both pump paths and the local alarm with the chosen battery and real discharge.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
WSS30Vn Combination System exact manufacturer recordWayne Water Systems · identity

Wayne Water Systems identifies exact model WSS30VN as a drop-in 1/2 HP primary and 12 V backup pair with separate switches, shared discharge, charger and audible backup alarm.

Source type
manufacturer
Content hash
8d8123e6a79747cb
Use
store excerpt
Open Wayne Water Systems
02
WSS30Vn Combination System exact current U.S. offerMajor U.S. home retailer · price

$567.36 current U.S. retail reference was retained for exact model WSS30VN. Confirm the upgraded N model, battery and check-valve exclusions and return terms, then measure the basin at the switch and inlet elevations before ordering

Source type
retailer
Content hash
7ed81ea04fe9eb4b
Use
store snapshot
Open Major U.S. home retailer
03
WSS30Vn Combination System exact manual and supportWayne Water Systems · specification

The AC CDU800 side is rated 5,100 GPH at zero and 3,840 at 10 feet; the 12 V side is rated 2,700 at zero and 1,500 GPH at 10 feet, so outage capacity must be compared at the actual head Wayne specifies at least a 15-inch tapered or 16-inch non-tapered pit and an assembly width near 14.875 inches; both pumps are groundwater sump pumps rather than sewage or debris pumps The AC vertical float and separate backup reed float require free movement; the preassembled pumps share a 1-1/2-inch discharge and require an installer-supplied check valve above the junction, leaving the valve and outlet as common failure points

Source type
support
Content hash
41192703e84bec88
Use
store excerpt
Open Wayne Water Systems
04
WSS30Vn Combination System power, monitoring and service boundaryWayne Water Systems · specification

The primary uses 120 V and the backup uses one separately purchased supported 12 V deep-cycle battery, with Wayne recommending WSB1275 75 Ah; charger status does not replace periodic capacity testing Wayne's hours-of-protection language depends on battery, head and cycling; the controller sounds an audible alarm when backup runs and has no built-in Wi-Fi or cloud notification Water-test both switches, remove AC power under observation, load-test battery, inspect charger lights, the shared check valve and exterior outlet and preserve room to pull the whole assembly for component replacement Current warranty documentation gives three-year limited coverage for WSS30Vn; dead battery, charger or reed-switch fault, AC switch fault, missing or failed check valve, blocked shared discharge, freeze, overwhelming inflow and unheard local alarm remain

Source type
support
Content hash
09d1f81059d244e5
Use
store excerpt
Open Wayne Water Systems
05
Mold, moisture and home cleanup boundaryU.S. Environmental Protection Agency · specification

EPA guidance centers moisture-source correction, prompt drying and appropriate remediation. A sump pump does not by itself stop leaks, dry materials or remediate mold.

Source type
editorial
Content hash
6c6e709376a3e687
Use
store excerpt
Open U.S. Environmental Protection Agency
06
Flood cleanup electrical and contamination hazardsU.S. Centers for Disease Control and Prevention · specification

Flood cleanup can involve electrical shock, sewage and chemical contamination, mold, unstable materials and injury hazards that require appropriate utilities, protective equipment and trained help.

Source type
editorial
Content hash
6e9efdb9c7e61047
Use
store excerpt
Open U.S. Centers for Disease Control and Prevention
07
Confined-space hazard frameworkU.S. Occupational Safety and Health Administration · specification

Pits and restricted spaces can contain hazardous atmospheres, engulfment or difficult rescue conditions. Entry requires an applicable assessment and controls rather than an assumption that a residential space is safe.

Source type
editorial
Content hash
ab8d29e3e9c650fc
Use
store excerpt
Open U.S. Occupational Safety and Health Administration
08
Flood insurance policy boundaryNational Flood Insurance Program · specification

Flood insurance coverage, exclusions, documentation and claim outcomes are policy- and event-specific. Equipment ownership or an alarm does not guarantee coverage, insurability or payment.

Source type
editorial
Content hash
80cd5f808af32009
Use
store excerpt
Open National Flood Insurance Program
09
Wayne WSS30Vn tested basement backup pumpBob Vila · specification

Hands-on testing flooded a basin, interrupted AC and observed the exact WSS30Vn continue on battery, while the review also records its large-basin fit and separate battery boundary.

Source type
editorial
Content hash
4fa7aa094eb02e34
Use
store excerpt
Open Bob Vila
10
Wayne WSS30VN exact owner reviewsHome Depot customers · consensus

Exact-model owners discuss quick installation, broad footprint, pump replacement access, alarm, battery purchase and outage operation. Reports cannot prove runtime or long-term reliability.

Source type
community
Content hash
cdfb84d8304796e7
Use
store excerpt
Open Home Depot customers
11
Aquanot Fit 508 ProPak with M53 defended comparison alternativeZoeller Pump Company · alternative

Aquanot Fit 508 ProPak with M53 is the professional preassembled connected combination alternative at $1,033.50 current U.S. street reference.

Source type
manufacturer
Content hash
87c95bd2a5f12d30
Use
store excerpt
Open Zoeller Pump Company
12
Basement Watchdog Big Combo CONNECT defended comparison alternativeGlentronics · alternative

Basement Watchdog Big Combo CONNECT is the mainstream monitored combination alternative at $469.00 current U.S. retail reference.

Source type
manufacturer
Content hash
abb6888ca97d2bf3
Use
store excerpt
Open Glentronics

Manufacturer identity, exact current U.S. price, current manual or support path, independent editorial, laboratory or professional-market evidence and bounded exact-model owner or installer evidence were checked on August 18, 2026. This desk covers complete current or actively supported residential basement and crawlspace primary sump pumps, battery-backup sump systems and integrated primary-plus-backup packages. It excludes sewage, effluent-tank, grinder and utility pumps; standalone batteries, chargers, alarms and power converters; water-powered backups; commercial lift stations; unsupported or obsolete models; marketplace-only products; and cosmetic bundles or package padding. Pump flow must be read on the exact curve at total dynamic head, including vertical rise and pipe, fitting and check-valve loss. Zero-head flow and horsepower do not size a system. Basin diameter, depth, inlet elevation, usable cycle volume, switch travel, solids boundary, discharge diameter, check valve, union, air-lock relief, exterior termination and freeze or backflow exposure are installation facts. Primary, backup and high-water switches must move freely and be tested independently. Battery chemistry, group size, amp-hours, age, temperature, charger, cable, voltage sag, duty cycle and head control useful backup time; no runtime claim is a site promise. Audible, dry-contact, Wi-Fi, app and cloud alerts have different hardware, power, account, network, service, privacy and delivery boundaries. Keep receptacles, controllers, chargers and batteries dry and above possible water, use direct grounded connections and required GFCI and branch protection, isolate power before contact and use qualified electrical and plumbing work plus required permits and inspections. Never enter a sump, basin, crawlspace or other possible confined space without the applicable competent-person assessment and controls. Floodwater may contain sewage, chemicals, sharp objects and energized equipment. Do not touch water or pumps where electrical or contamination hazards may exist; use emergency, utility, remediation and public-health guidance. A sump system does not stop groundwater, sewer backup, plumbing failure, mold, backflow or contaminated flooding and does not replace drainage, grading, waterproofing, sewer protection, mold remediation, flood cleanup or a site-specific professional design. No product, curve, test, review, alarm, battery, warranty or installation guarantees flood prevention, runtime, notification, reliability, service life, mold prevention, property protection, code approval, permit acceptance, insurability, coverage or an insurance claim outcome.

Researching another model?

Search the current market