Market IndexProduct intelligenceSump pumps and backupsSearch products
All marketsPremium home sump-pump and backup systemsWayne Water Systems

Wayne Water Systems · CDU800

CDU800

A top-suction primary with fixed vertical switch, strong medium-head flow and a compact 11-inch basin claim
Market statusCurrent 1/2 HP cast-iron primary sump pumpChecked Aug 18
Reference price$158.78 current U.S. retail referenceHome Depot exact CDU800 current reference
Product cyclecurrentRelease history under review
EvidenceWell supported9 publishers · 6 independent
Next full checkAug 25, 2026Price checks run sooner
01

Ready to buy

Confirm the exact pump, package and installation

The retained reference is $158.78 current U.S. retail reference. Confirm CDU800 rather than steel or different-switch relatives and add the exact valve, union, alarm and backup needed by the installation. Commission every pump, float, check valve, alarm and notification path before relying on the installation.

02

Current market

The facts that change the ownership choice

Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.

QuestionCurrent answerFreshnessBasis

Current price

$158.78 current U.S. retail reference

Confirm CDU800 rather than steel or different-switch relatives and add the exact valve, union, alarm and backup needed by the installation. Confirm exact current stock, seller authorization, tax, delivery, battery, valves, pipe, alarm, labor, permits and return terms before paying.

Refresh due soonDirect source1 evidence item

System branch

Value high-flow primary
Checked 6 days agoOur synthesis2 evidence items

Complete-purchase boundary

CDU800 combines high published flow and a compact switch but includes no check valve, alarm or backup; the fixed 9-inch-on cycle must work with the real inlet elevation and basin volume
Checked 6 days agoOur synthesis4 evidence items

Head and flow boundary

Wayne publishes 5,100 GPH at zero head, 4,500 at 5 feet, 3,840 at 10 feet, 3,060 at 15 feet and 2,040 at 20 feet; size from total dynamic head, not the zero-head headline
Checked 6 days agoOur synthesis2 evidence items

Basin fit and solids boundary

Wayne states an 11-inch-or-larger basin and top suction intended to reduce air lock and debris intake; no sewage or grinder solids capability is admitted and sediment still needs removal
Checked 6 days agoOur synthesis3 evidence items

Switch, check valve and discharge

The integral vertical float turns on near 9 inches and off near 4 inches and needs wall, cord and inlet clearance; provide a 1-1/2-inch NPT discharge, union and separately purchased check valve
Checked 6 days agoOur synthesis3 evidence items

Power, battery and charger

The 120 V PSC oil-filled motor uses a grounded GFCI-protected direct receptacle and suitable circuit; there is no battery, charger or outage supply
Checked 6 days agoOur synthesis3 evidence items

Runtime, alarm and connection

CDU800 has no battery runtime, alarm or connectivity, so a separate high-water alarm and independent backup decision remain
Checked 6 days agoOur synthesis3 evidence items

Maintenance, access and service

Run multiple water cycles, inspect top suction, float guard, check valve and freeze-safe outlet and keep removal clearance; disconnect power before pit work
Checked 6 days agoOur synthesis4 evidence items

Warranty and failure modes

The exact model has three-year limited coverage; float hang-up, short cycling, seal or motor fault, loss of power, check-valve leak, clogged or frozen discharge and excess inflow remain possible
Checked 6 days agoOur synthesis3 evidence items

Shock, flood, mold, sewage and outcome boundary

This system cannot make energized or contaminated water safe, prevent groundwater or sewer backflow, remove mold, authorize confined-space entry, satisfy every electrical or plumbing code, permit or insurance requirement or guarantee flood prevention, runtime, notification, reliability, property protection, coverage or a claim outcome.
Checked 6 days agoOur synthesis5 evidence items

Current verdict

The strong value primary

CDU800 is the lower-cost high-flow choice when 3,840 GPH at 10 feet fits the calculated duty and the fixed switch cycle will not expose the inlet or cause rapid cycling.

Checked 6 days agoOur synthesis12 evidence items
03

Other paths

The alternatives change what the CDU800 is worth

These are not generic competitors. Each one represents a different way to buy into the same market.

01ownership

Zoeller Pump Company

M53 Mighty-Mate

$224.25 current U.S. street reference
Best fit
Cast-iron primary for a compact conventional basin
Tradeoff
The M53 is a pump, switch and cord rather than a complete backup plan; it needs a correctly sized basin, separate full-flow check valve, supported discharge and a separately designed alarm or backup system
Open the source
02premium

Wayne Water Systems

CDU980E

$211.78 current U.S. retail reference
Best fit
High-head compact primary
Tradeoff
CDU980E's large curve can worsen short cycling or expose a restrictive discharge, and the pump still has no backup, alarm or included check valve
Open the source
04

What changed

The product has a history

Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.

  1. notable

    Current exact pump, package, price and failure boundary retained

    CDU800 was checked against exact manufacturer identity and manual, current U.S. price, hydraulic curve, basin and switch fit, discharge and check-valve path, power or battery system, alarm and connectivity, service, independent evidence and bounded owner or installer reports.

Price record

The price history starts here

Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.

  1. $158.78 current U.S. retail reference

    Current reference priceA structured timeline will begin with the next source capture

05

Owner experience

What repeats after the purchase

Owner and installer discussion returns to fixed-cycle fit, noise, storm cycling, float behavior, corrosion and replacement dimensions rather than a universal reliability or flood result.

These are self-reported experiences across different basins, inflows, heads, pipe and check-valve layouts, circuits, batteries, chargers, alarms, networks, maintenance, installation quality, weather and service ages. They identify commissioning and service checks and do not establish standardized flow, runtime, notification delivery, reliability, failure rate, flood prevention, mold prevention, safety, code approval, insurability or claim outcomes.
SignalWhat owners reportOur readEvidence

fixed-cycle fit, noise, storm cycling, float behavior, corrosion and replacement dimensions

Exact-model owners discuss noise, rapid storm cycling, float operation, replacement fit and corrosion. Self-selected reports do not establish cycle life or reliability.

Measure the real pit cycle volume and head, then observe repeated starts and check-valve closure before deciding that high catalog flow solves the system.

1 evidence record
06

Sources

Why we believe the current view

The page separates what a source states directly from what we conclude across sources.

01
CDU800 exact manufacturer recordWayne Water Systems · identity

Wayne Water Systems identifies exact model CDU800 as a top-suction primary with fixed vertical switch, strong medium-head flow and a compact 11-inch basin claim.

Source type
manufacturer
Content hash
2eb1b146a0d8f546
Use
store excerpt
Open Wayne Water Systems
02
CDU800 exact current U.S. offerMajor U.S. home retailer · price

$158.78 current U.S. retail reference was retained for exact model CDU800. Confirm CDU800 rather than steel or different-switch relatives and add the exact valve, union, alarm and backup needed by the installation

Source type
retailer
Content hash
0cf326a87daac814
Use
store snapshot
Open Major U.S. home retailer
03
CDU800 exact manual and supportWayne Water Systems · specification

Wayne publishes 5,100 GPH at zero head, 4,500 at 5 feet, 3,840 at 10 feet, 3,060 at 15 feet and 2,040 at 20 feet; size from total dynamic head, not the zero-head headline Wayne states an 11-inch-or-larger basin and top suction intended to reduce air lock and debris intake; no sewage or grinder solids capability is admitted and sediment still needs removal The integral vertical float turns on near 9 inches and off near 4 inches and needs wall, cord and inlet clearance; provide a 1-1/2-inch NPT discharge, union and separately purchased check valve

Source type
support
Content hash
e5130a47a35f7fe1
Use
store excerpt
Open Wayne Water Systems
04
CDU800 power, monitoring and service boundaryWayne Water Systems · specification

The 120 V PSC oil-filled motor uses a grounded GFCI-protected direct receptacle and suitable circuit; there is no battery, charger or outage supply CDU800 has no battery runtime, alarm or connectivity, so a separate high-water alarm and independent backup decision remain Run multiple water cycles, inspect top suction, float guard, check valve and freeze-safe outlet and keep removal clearance; disconnect power before pit work The exact model has three-year limited coverage; float hang-up, short cycling, seal or motor fault, loss of power, check-valve leak, clogged or frozen discharge and excess inflow remain possible

Source type
support
Content hash
d27c2335b92a371b
Use
store excerpt
Open Wayne Water Systems
05
Mold, moisture and home cleanup boundaryU.S. Environmental Protection Agency · specification

EPA guidance centers moisture-source correction, prompt drying and appropriate remediation. A sump pump does not by itself stop leaks, dry materials or remediate mold.

Source type
editorial
Content hash
6c6e709376a3e687
Use
store excerpt
Open U.S. Environmental Protection Agency
06
Flood cleanup electrical and contamination hazardsU.S. Centers for Disease Control and Prevention · specification

Flood cleanup can involve electrical shock, sewage and chemical contamination, mold, unstable materials and injury hazards that require appropriate utilities, protective equipment and trained help.

Source type
editorial
Content hash
6e9efdb9c7e61047
Use
store excerpt
Open U.S. Centers for Disease Control and Prevention
07
Confined-space hazard frameworkU.S. Occupational Safety and Health Administration · specification

Pits and restricted spaces can contain hazardous atmospheres, engulfment or difficult rescue conditions. Entry requires an applicable assessment and controls rather than an assumption that a residential space is safe.

Source type
editorial
Content hash
ab8d29e3e9c650fc
Use
store excerpt
Open U.S. Occupational Safety and Health Administration
08
Flood insurance policy boundaryNational Flood Insurance Program · specification

Flood insurance coverage, exclusions, documentation and claim outcomes are policy- and event-specific. Equipment ownership or an alarm does not guarantee coverage, insurability or payment.

Source type
editorial
Content hash
80cd5f808af32009
Use
store excerpt
Open National Flood Insurance Program
09
Wayne CDU800 current technical comparisonPumpingChops · specification

Independent current comparison preserves the exact 3,840 GPH at 10-foot point, vertical switch, 1-1/2-inch discharge and material tradeoff instead of ranking by horsepower alone.

Source type
editorial
Content hash
b0cf017c012320e0
Use
store excerpt
Open PumpingChops
10
Wayne CDU800 exact owner reviewsHome Depot customers · consensus

Exact-model owners discuss noise, rapid storm cycling, float operation, replacement fit and corrosion. Self-selected reports do not establish cycle life or reliability.

Source type
community
Content hash
4040bab80130a6cd
Use
store excerpt
Open Home Depot customers
11
M53 Mighty-Mate defended comparison alternativeZoeller Pump Company · alternative

M53 Mighty-Mate is the cast-iron primary for a compact conventional basin alternative at $224.25 current U.S. street reference.

Source type
manufacturer
Content hash
f3edcf9ef22946ae
Use
store excerpt
Open Zoeller Pump Company
12
CDU980E defended comparison alternativeWayne Water Systems · alternative

CDU980E is the high-head compact primary alternative at $211.78 current U.S. retail reference.

Source type
manufacturer
Content hash
4521a87455f90d33
Use
store excerpt
Open Wayne Water Systems

Manufacturer identity, exact current U.S. price, current manual or support path, independent editorial, laboratory or professional-market evidence and bounded exact-model owner or installer evidence were checked on August 18, 2026. This desk covers complete current or actively supported residential basement and crawlspace primary sump pumps, battery-backup sump systems and integrated primary-plus-backup packages. It excludes sewage, effluent-tank, grinder and utility pumps; standalone batteries, chargers, alarms and power converters; water-powered backups; commercial lift stations; unsupported or obsolete models; marketplace-only products; and cosmetic bundles or package padding. Pump flow must be read on the exact curve at total dynamic head, including vertical rise and pipe, fitting and check-valve loss. Zero-head flow and horsepower do not size a system. Basin diameter, depth, inlet elevation, usable cycle volume, switch travel, solids boundary, discharge diameter, check valve, union, air-lock relief, exterior termination and freeze or backflow exposure are installation facts. Primary, backup and high-water switches must move freely and be tested independently. Battery chemistry, group size, amp-hours, age, temperature, charger, cable, voltage sag, duty cycle and head control useful backup time; no runtime claim is a site promise. Audible, dry-contact, Wi-Fi, app and cloud alerts have different hardware, power, account, network, service, privacy and delivery boundaries. Keep receptacles, controllers, chargers and batteries dry and above possible water, use direct grounded connections and required GFCI and branch protection, isolate power before contact and use qualified electrical and plumbing work plus required permits and inspections. Never enter a sump, basin, crawlspace or other possible confined space without the applicable competent-person assessment and controls. Floodwater may contain sewage, chemicals, sharp objects and energized equipment. Do not touch water or pumps where electrical or contamination hazards may exist; use emergency, utility, remediation and public-health guidance. A sump system does not stop groundwater, sewer backup, plumbing failure, mold, backflow or contaminated flooding and does not replace drainage, grading, waterproofing, sewer protection, mold remediation, flood cleanup or a site-specific professional design. No product, curve, test, review, alarm, battery, warranty or installation guarantees flood prevention, runtime, notification, reliability, service life, mold prevention, property protection, code approval, permit acceptance, insurability, coverage or an insurance claim outcome.