Next full checkAug 25, 2026Price checks run sooner
01
Ready to buy
Confirm the exact pump, package and installation
The retained reference is $323.25 current U.S. street reference. Confirm 115 V model 287 rather than 287HV or longer-cord suffixes and size the check valve and discharge to the curve. Commission every pump, float, check valve, alarm and notification path before relying on the installation.
Buying stageMarket familiarity
02
Current market
The facts that change the ownership choice
Each line carries its own check date because price, software, specifications, and product cycle do not age at the same speed.
QuestionCurrent answerFreshnessBasis
Current price
$323.25 current U.S. street reference
Confirm 115 V model 287 rather than 287HV or longer-cord suffixes and size the check valve and discharge to the curve. Confirm exact current stock, seller authorization, tax, delivery, battery, valves, pipe, alarm, labor, permits and return terms before paying.
Refresh due soonDirect source1 evidence item
System branch
High-flow serviceable cast-iron primary
Checked 6 days agoOur synthesis2 evidence items
Complete-purchase boundary
The 287's larger solids passage is a clog-resistance fact for suitable groundwater or effluent, not permission for sewage, and its eight-amp motor and high curve require circuit and cycle-volume checks
Checked 6 days agoOur synthesis4 evidence items
Head and flow boundary
The current 280-series performance curve places model 287 around 63 GPM at zero head, 55 GPM at 10 feet and 50 GPM at 15 feet with shutoff near 37 feet; select from the exact curve at total dynamic head
Checked 6 days agoOur synthesis2 evidence items
Basin fit and solids boundary
The vertical magnetic float and one-piece body need sufficient basin clearance and the pump passes up to 3/4-inch spherical solids; sewage, fibrous wipes and grinder duty remain excluded
Checked 6 days agoOur synthesis3 evidence items
Switch, check valve and discharge
The automatic magnetic vertical float turns on near 9-1/2 inches and off near 4 inches and needs clean, free travel; provide 1-1/2-inch discharge, full-flow check valve, union and required vent or relief detail
Checked 6 days agoOur synthesis3 evidence items
Power, battery and charger
The 1/2 HP 115 V motor is rated 8.0 A with 23 A locked-rotor current and a quick-connect grounded cord; no battery or charger is included
Checked 6 days agoOur synthesis3 evidence items
Runtime, alarm and connection
No backup runtime, alarm or remote monitoring is present; plan independent notification and backup around actual consequences
Checked 6 days agoOur synthesis3 evidence items
Maintenance, access and service
Water-test the switch, inspect bottom screen, cord seal, check valve and outlet and monitor cycle frequency; use qualified service and disconnect power before pit contact
Checked 6 days agoOur synthesis4 evidence items
Warranty and failure modes
The series carries three-year limited coverage; higher solids clearance does not eliminate float, cord, seal, blockage, recirculation, freeze, power-loss or overwhelming-flow failures
Checked 6 days agoOur synthesis3 evidence items
Shock, flood, mold, sewage and outcome boundary
This system cannot make energized or contaminated water safe, prevent groundwater or sewer backflow, remove mold, authorize confined-space entry, satisfy every electrical or plumbing code, permit or insurance requirement or guarantee flood prevention, runtime, notification, reliability, property protection, coverage or a claim outcome.
Checked 6 days agoOur synthesis5 evidence items
Current verdict
The high-flow Liberty primary
Liberty 287 fits a higher-flow pit where the vertical magnetic switch clears the basin and cord serviceability matters.
Checked 6 days agoOur synthesis12 evidence items
03
Other paths
The alternatives change what the 287 is worth
These are not generic competitors. Each one represents a different way to buy into the same market.
01lower upfront
Liberty Pumps
257
$216.75 current U.S. street reference
Best fit
Compact serviceable cast-iron primary
Tradeoff
The 257's serviceable cord and magnetic float do not add backup, alarm or check valve, and its 1/2-inch solids label does not admit sewage to a residential groundwater sump
The M98's higher draw and start current require circuit and generator checks, and a larger pump can short-cycle in a small basin without fixing a restrictive discharge
Older observations stay in the ledger when the current view changes. That lets a buyer tell the difference between an old complaint, an active issue, and a problem that was corrected.
notable
Current exact pump, package, price and failure boundary retained
287 was checked against exact manufacturer identity and manual, current U.S. price, hydraulic curve, basin and switch fit, discharge and check-valve path, power or battery system, alarm and connectivity, service, independent evidence and bounded owner or installer reports.
Price record
The price history starts here
Each amount stays tied to its source and capture date. Conflicting prices remain visible until the seller resolves them.
$323.25 current U.S. street reference
Current reference priceA structured timeline will begin with the next source capture
05
Owner experience
What repeats after the purchase
Owner and installer discussion returns to magnetic float fit, high-flow cycling, start load, cord replacement and professional selection rather than a universal reliability or flood result.
These are self-reported experiences across different basins, inflows, heads, pipe and check-valve layouts, circuits, batteries, chargers, alarms, networks, maintenance, installation quality, weather and service ages. They identify commissioning and service checks and do not establish standardized flow, runtime, notification delivery, reliability, failure rate, flood prevention, mold prevention, safety, code approval, insurability or claim outcomes.
SignalWhat owners reportOur readEvidence
magnetic float fit, high-flow cycling, start load, cord replacement and professional selection
Exact-model purchasers discuss compact switch fit, high flow, installer selection and replacement. The limited sample cannot prove durability or failure frequency.
Check locked-rotor margin, calculate cycle volume and commission the pump at the exterior outlet rather than equating 1/2 HP with adequate system capacity.
1 evidence record
06
Sources
Why we believe the current view
The page separates what a source states directly from what we conclude across sources.
287 exact current U.S. offerProfessional U.S. retailer · price
$323.25 current U.S. street reference was retained for exact model 287. Confirm 115 V model 287 rather than 287HV or longer-cord suffixes and size the check valve and discharge to the curve
287 exact manual and supportLiberty Pumps · specification
The current 280-series performance curve places model 287 around 63 GPM at zero head, 55 GPM at 10 feet and 50 GPM at 15 feet with shutoff near 37 feet; select from the exact curve at total dynamic head The vertical magnetic float and one-piece body need sufficient basin clearance and the pump passes up to 3/4-inch spherical solids; sewage, fibrous wipes and grinder duty remain excluded The automatic magnetic vertical float turns on near 9-1/2 inches and off near 4 inches and needs clean, free travel; provide 1-1/2-inch discharge, full-flow check valve, union and required vent or relief detail
287 power, monitoring and service boundaryLiberty Pumps · specification
The 1/2 HP 115 V motor is rated 8.0 A with 23 A locked-rotor current and a quick-connect grounded cord; no battery or charger is included No backup runtime, alarm or remote monitoring is present; plan independent notification and backup around actual consequences Water-test the switch, inspect bottom screen, cord seal, check valve and outlet and monitor cycle frequency; use qualified service and disconnect power before pit contact The series carries three-year limited coverage; higher solids clearance does not eliminate float, cord, seal, blockage, recirculation, freeze, power-loss or overwhelming-flow failures
Mold, moisture and home cleanup boundaryU.S. Environmental Protection Agency · specification
EPA guidance centers moisture-source correction, prompt drying and appropriate remediation. A sump pump does not by itself stop leaks, dry materials or remediate mold.
Flood cleanup electrical and contamination hazardsU.S. Centers for Disease Control and Prevention · specification
Flood cleanup can involve electrical shock, sewage and chemical contamination, mold, unstable materials and injury hazards that require appropriate utilities, protective equipment and trained help.
Confined-space hazard frameworkU.S. Occupational Safety and Health Administration · specification
Pits and restricted spaces can contain hazardous atmospheres, engulfment or difficult rescue conditions. Entry requires an applicable assessment and controls rather than an assumption that a residential space is safe.
Flood insurance policy boundaryNational Flood Insurance Program · specification
Flood insurance coverage, exclusions, documentation and claim outcomes are policy- and event-specific. Equipment ownership or an alarm does not guarantee coverage, insurability or payment.
Liberty 287 independent professional-market coverageSupplyHouse · specification
Professional-market coverage verifies the exact 287 package, manuals, electrical data, current stock and price and separates it from high-voltage and cord variants.
Manufacturer identity, exact current U.S. price, current manual or support path, independent editorial, laboratory or professional-market evidence and bounded exact-model owner or installer evidence were checked on August 18, 2026. This desk covers complete current or actively supported residential basement and crawlspace primary sump pumps, battery-backup sump systems and integrated primary-plus-backup packages. It excludes sewage, effluent-tank, grinder and utility pumps; standalone batteries, chargers, alarms and power converters; water-powered backups; commercial lift stations; unsupported or obsolete models; marketplace-only products; and cosmetic bundles or package padding. Pump flow must be read on the exact curve at total dynamic head, including vertical rise and pipe, fitting and check-valve loss. Zero-head flow and horsepower do not size a system. Basin diameter, depth, inlet elevation, usable cycle volume, switch travel, solids boundary, discharge diameter, check valve, union, air-lock relief, exterior termination and freeze or backflow exposure are installation facts. Primary, backup and high-water switches must move freely and be tested independently. Battery chemistry, group size, amp-hours, age, temperature, charger, cable, voltage sag, duty cycle and head control useful backup time; no runtime claim is a site promise. Audible, dry-contact, Wi-Fi, app and cloud alerts have different hardware, power, account, network, service, privacy and delivery boundaries. Keep receptacles, controllers, chargers and batteries dry and above possible water, use direct grounded connections and required GFCI and branch protection, isolate power before contact and use qualified electrical and plumbing work plus required permits and inspections. Never enter a sump, basin, crawlspace or other possible confined space without the applicable competent-person assessment and controls. Floodwater may contain sewage, chemicals, sharp objects and energized equipment. Do not touch water or pumps where electrical or contamination hazards may exist; use emergency, utility, remediation and public-health guidance. A sump system does not stop groundwater, sewer backup, plumbing failure, mold, backflow or contaminated flooding and does not replace drainage, grading, waterproofing, sewer protection, mold remediation, flood cleanup or a site-specific professional design. No product, curve, test, review, alarm, battery, warranty or installation guarantees flood prevention, runtime, notification, reliability, service life, mold prevention, property protection, code approval, permit acceptance, insurability, coverage or an insurance claim outcome.